background image

SmartGen Encoders Manager

STEP 6

1

3

4

Upon completion of the instillation process, a shortcut to the software will appear on the 

desktop of your PC. A double click on the shortcut will open the main application window. 

Most of the functions will be disabled. In order to enable them, a connection with the 

device should be established. 

See below the control window representation:

Communication Mode Configuration

STEP 7

1. Press  the  'Settings'  button,  located  on  the 

bottom-left corner 

.

Settings dialog window will 

appear; 

2. Click on the 

Refresh button

 

 and using the drop 

down menu select the proper COM Port. ;

3. Press OK and exit the Settings Menu; 
4. Different  communication  modes  can  be  easily 

changed via the short-cut placed on the bottom 
right  of  the  screen 

.  Select  COM 

communication mode and press Connect; 

5. Once  read,  the  Hardware  configuration  will  be 

visible  and  ready  for  editing.  The  Basic  and 
Advanced  RDS  and  the  Console  tabs  will  be 
activated.

(1)  

(2)

(3)

2

NOTE:

Please note that upon completion of the USB installation process, the USB will be referred to as 
COM port. The COM port number varies depending on  the number of COM connections.
The connection status is visible on the bottom-right part of the screen 

.

(4)

Содержание SmartGen 4.1

Страница 1: ...dcast com SmartGen 4 1 UECP Compatible RDS RBDS Encoder with LAN USB Connectivity Quick User Guide BEFORE YOU USE THIS PRODUCT In order to be able to enjoy all the benefits of owning your new DEVA product please verify first that the latest software and firmware release were installed Visit www devabroadcast com downloads recent software and firmware downloads prior the installation for the most ...

Страница 2: ...Installation STEP 2 1 www devabroadcast com downloads 2 Find SmartGen 4 1 folder and double click on the installation file to launch the Wizard 3 Accept the default recommendations and select Next in the end of each step 4 When asked to place an icon on the Desktop of your computer make sure that the check box is enabled and click Next Finish 5 Finally select NOTto launch the program Use the Insta...

Страница 3: ...signal is not routed through SmartGen Mini This operating mode preserves the multiplex signal integrity and assures uninterrupted program transmission in case of encoder failure event Originally SmartGen 4 1 is configured for sidechain operation Sidechain Encoder Connection 1 Connect a BNC T adapter to the composite MPX output of the stereo generator 2 Using a suitable cable connect one side of th...

Страница 4: ...will appear 2 Click on the Refresh button and using the drop down menu select the proper COM Port 3 Press OK and exit the Settings Menu 4 Different communication modes can be easily changed via the short cut placed on the bottom right of the screen Select COM communication mode and press Connect 5 Once read the Hardware configuration will be visible and ready for editing The Basic and Advanced RDS...

Страница 5: ...am Type identifies the station s programming format from a list There are two lists for the European RDS system and for theAmerican RBDS specification The proper PTY can be selected from a drop down menu TATimeout An automatic timeout option has been included into SmartGen 4 1 to prevent from an extended software activated TA flag The timeout can be set choosing between 1 and 255 minutes This will...

Отзывы: