Loop-through operation mode

STEP 5

If Loop-through operation mode is chosen, the RDS OR MPX OUTPUT includes the composite MPX 

program signal to the RDS sub carrier. In loop-through mode the internal bypass relay will pass-through 
the multiplex signal in case of an encoder power failure event. 

"Loop-through" Encoder Connection

1.

generator directly to the PILOT OR MPX 
INPUT of SmartGen 4.1;

2. Connect  the  RDS  OR  MPX  OUTPUT  of 

the  encoder  to  the  composite/MPX 
wideband input of the FM exciter. 

Connect  the  output  of  the  stereo 

Sidechain operating mode

STEP 4

In  order  to  derive  timing  information  from  the  19kHz  stereo  pilot,  the  rear-panel  PILOT  OR  MPX 

INPUT connector monitors the output of the stereo generator. When sidechain operation mode is chosen 
the RDS OR MPX OUTPUT contains only the RDS sub carrier, the composite MPX signal is not routed 
through  SmartGen  Mini.  This  operating  mode  preserves  the  multiplex  signal  integrity  and  assures 
uninterrupted  program  transmission,  in  case  of  encoder  failure  event.  Originally  SmartGen  4.1  is 
configured for sidechain operation.

"Sidechain" Encoder Connection

1. Connect  a  BNC  'T'  adapter  to  the 

composite/MPX  output  of  the  stereo 
generator;

2. Using a suitable cable, connect one side 

of the 'T' adapter directly to the wideband 
(composite/ MPX) input of the FM exciter;

3. Using a suitable cable, connect the other 

side  of  the  'T'  adapter  to  the  PILOT  OR 
MPX INPUT of SmartGen 4.1;

4. Cable the RDS OR MPX OUTPUT of the 

encoder  to  the  second  wideband 
(subcarrier) input of the FM exciter. 

NOTE: 

We strongly recommend the usage 

of Sidechain operating mode.

FM STEREO GENERATOR

MPX OUTPUT

SmartGen 

4.1

RDS OR MPX

OUTPUT

PILOT OR MPX

INPUT

1

2

3

WIDEBAND INPUTS

FM EXCITER / TRANSMITTER

LAN

1

2

4

3

FM STEREO GENERATOR

MPX OUTPUT

SmartGen 4.1

RDS OR MPX

OUTPUT

PILOT OR MPX

INPUT

1

2

3

WIDEBAND INPUTS

FM EXCITER / TRANSMITTER

LAN

1

2

Содержание SmartGen 4.1

Страница 1: ...dcast com SmartGen 4 1 UECP Compatible RDS RBDS Encoder with LAN USB Connectivity Quick User Guide BEFORE YOU USE THIS PRODUCT In order to be able to enjoy all the benefits of owning your new DEVA product please verify first that the latest software and firmware release were installed Visit www devabroadcast com downloads recent software and firmware downloads prior the installation for the most ...

Страница 2: ...Installation STEP 2 1 www devabroadcast com downloads 2 Find SmartGen 4 1 folder and double click on the installation file to launch the Wizard 3 Accept the default recommendations and select Next in the end of each step 4 When asked to place an icon on the Desktop of your computer make sure that the check box is enabled and click Next Finish 5 Finally select NOTto launch the program Use the Insta...

Страница 3: ...signal is not routed through SmartGen Mini This operating mode preserves the multiplex signal integrity and assures uninterrupted program transmission in case of encoder failure event Originally SmartGen 4 1 is configured for sidechain operation Sidechain Encoder Connection 1 Connect a BNC T adapter to the composite MPX output of the stereo generator 2 Using a suitable cable connect one side of th...

Страница 4: ...will appear 2 Click on the Refresh button and using the drop down menu select the proper COM Port 3 Press OK and exit the Settings Menu 4 Different communication modes can be easily changed via the short cut placed on the bottom right of the screen Select COM communication mode and press Connect 5 Once read the Hardware configuration will be visible and ready for editing The Basic and Advanced RDS...

Страница 5: ...am Type identifies the station s programming format from a list There are two lists for the European RDS system and for theAmerican RBDS specification The proper PTY can be selected from a drop down menu TATimeout An automatic timeout option has been included into SmartGen 4 1 to prevent from an extended software activated TA flag The timeout can be set choosing between 1 and 255 minutes This will...

Отзывы: