ALARM NOTIFICATIONS
The E-mail, SMS, SNMP trap Alarm Notifications contain the following information - device’s
Alias, date and time of Alarm triggered, channel number, frequency and information about the
Alarm activation/deactivation. The basic signal parameters are also included.
Example for E-mal Notification:
Date: 04 Nov 2018, 07:31:11
DB7012 reports ACTIVE alarm on 0x1234 - Power FM (CH1)
Alarm: S/N Ratio < 16dB
Signal parameters:
RF: 31dBuV
DAB: LOSS
S/N Ratio: 0dB
CNR: 0dB
Left: -60.0dB
Right: -60.0dB
FIC Quality: 0%
Example for SMS Notification:
ACTIVE ALARM:CH1
27.09.2018 09:08:34
SERV:0x1234
RF:31dBuV
DAB:LOSS
SNR:0dB *L*
CND:0dB
Left:-60.0dB
Right:-60.0dB
FICQ:0%
NOTE:
*L* for LOW (below threshold), *H* for HIGH (above threshold)
ATTENTION:
Because of the SMS length limitations, only the most important parameters are
included.