Channel
•
[Enabled] / [Disabled] channel monitoring and sending of warnings and alarms. If the
channel is not generally enabled, the frequency will not be monitored and alarm notifications
will not be received;
•
Frequency – specify the frequency to be monitored;
•
Name – channel alias. The same name will appear on the quick access buttons in the
“dashboard”;
•
Acquisition time – specify the observation time for the current station (before switching to
the next channel).
• E-mail – set email address that will receive warning and alarm notifications for this service
only.
NOTE:
When MPX Power alarm is enabled the observation time must be more than 70 seconds.
NOTE:
In order to have correct Long-term loudness value logged in log file channel observation
time must be more than the Long-term loudness measurement sliding time window (see
).
Alarm
•
Alarm Range – interactive slider used to adjust the Low & High thresholds at which an
alarm will be generated;
•
Warning Range – interactive slider used to adjust the Low & High thresholds at which a
warning will be generated;
•
Threshold – buttons to enable/disable alarm range limits;
•
Trigger Time – waiting time before Active Alarm/Warning is generated;
•
Release Time – waiting time before Idle Alarm/Warning is generated;
•
RDS/RBDS Group Alarm – alarm only for selected groups will be generated.
IMPORTANT NOTE:
Warnings and alarms are generated only when the Logger mode is
running. While there is any user interaction, warning or alarm will not be generated and send. The
Logger starts running once the user logs out of the WEB interface.
Trigger and Release times define the time, which should elapse in order for the received signal
to be defined as low/high/lost or restored/OK. What we recommend is the release time to be bigger
than the trigger time.
NOTE:
When setting Trigger and Release times, have in mind that 01:00 means 1 minute, and
00:01 means 1 second.
NOTE:
In order for the applied settings to be used press the [Save] button, placed on the
bottom right part of the screen.