65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 70 -
SNMP Agent
Specify Agent ID, Agent Port, Read/Write Communities, Manager IP, Manager Port and session
timeout.
Agent - enables/disables SNMP Agent.
Agent ID is used for identification of the device among others, when an SNMP notification is
being sent.
Once all needed settings are applied, use the Test button to generate a test notification, which
upon success will be received by the SNMP Manager.
Press the ‘Download’ button to download the latest available DB4004 SNMP MIB file.
NOTE:
The MIB file may vary from one firmware revision to another. Downloading this file
from the device, guarantees that you have the proper MIB file.
Syslog
Enable or disable the Syslog feature. Specify Server address and port to be used.
GSM Modem
Up to five numbers for SMS control and alarm notifications could be set. Baud Rate is mandatory
for the proper operation of the GSM Modem.
We recommend that a test SMS to be generated (via pressing the ‘Test’ button), once all needed
settings are applied. Upon success, the SMS will be delivered to all the specified GSM numbers.
Example of Test SMS Message:
DB4004 Test Message.
NOTE:
The current condition of the GSM Modem could be checked in the “Status Screen”.
Application Server
Enable/Disable the DEVA Device Manger Application Server. Specify the Server Port and
session timeout.
Audio Stream Server
Specify Port for audio Streaming, and Quality (64, 96, 128, 192 or 256 kbps). The Audio Stream
could be heard using suitable audio player (Media Player, Winamp, etc.) or through the WEB
interface by pressing the “Listen” button.
Enter the desired alarm recipients in e-mail 1 and/or e-mail 2 fields. Fill in your e-mail account
settings: Sender, Username and Password, Server, SNMP port and connection type.
We recommend you to use the ‘Test’ button and generate a test e-mail, which upon success will
be delivered to the specified E-mail 1 and/or E-mail 2.
Example of Test E-mail Message:
DB4004 Test Message.
Please do not reply to this e-mail.
USB Port
Enable/Disable the USB port.
WARNING:
The applied changes will take effect upon pressing the “Save” button. All settings
marked with require Reboot, therefore the Save & Reboot button should be used.
NOTE:
The edited field will become red if the new value is invalid or out of range.