65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 64 -
GENERAL SETTINGS SCREEN
DB4004 provides you with protected access to the device settings. You can choose between two
types of log in.
•
As an
Administrator
– It will give you full control over the settings of the device;
•
As a
User
– that will allow you to just monitor the device and to choose different stations,
while the Settings bar remains locked.
In order for the security of DB4004 to be enhanced, a new username and password could be set
from the “Security” section.
By choice, you can change the name of the device (“General” section). Later on, it will be used
as a title name for all WEB pages. Customizing the name will make the device more recognizable.
Fan control
– set the preferred speed of the built-in Fan.
Date & Time
– used for manually set the current Date and Time. “Copy Local Time” button
will set the Date and Time to correspond to that of your computer.
SNTP Internet Time
– Synchronizes automatically the DB4004 clock to a millisecond with the
Internet time server. Enable this function in order to use it. (Specifying the server closest to your
location will improve the accuracy).
Temperature Alarm
– Detects abnormal temperature of the equipment. Define the parameters
under which a temperature alarm to be generated;
Fan Alarm
– Detects abnormal operation of the built-in fan. Define the parameters under which
a fan alarm to be generated;
WEB Log
– the maximum storage time of the System Log file is chosen from here. If the file
is older than the specified maximum will be deleted.
NOTE:
In order for the applied settings to be used press the “Save” button, placed on the
bottom right part of the screen.
Содержание DB4004
Страница 5: ...THIS PAGE IS INTENTIONALLY LEFT BLANK ...