Instruction manual LOCON 100 / 200 and ROTARNOCK 80 / 100 with fieldbus connection V. 1.0
15
Deutschmann Automation GmbH & Co. KG
Offset-table
6.13
Example: Parameter-table
Address in dez
Description
Length
Value in dez
0
Offset_Type
WORD
1
2
Offset_Length
WORD
12
4
Offset_Address
WORD
0
6
Cam_MT_Type
WORD
3
8
Cam_MT_Length
WORD
6
10
Cam_MT_Address
WORD
12
12
Cam_MT_Cam (1).ProgNo
WORD
0
14
Cam_MT_Cam (1).Output
WORD
4
16
Cam_MT_Cam (1).On
DWORD
20
18
Cam_MT_Cam (1).Off
DWORD
40
In this example the output 4, Cam_MT_Cam(1).Output is set in the program 0,
Cam_MT_Cam(1).ProgNr., between position 20, Cam_MT_Cam(1).On and 40,
Cam_MT_Cam(1).Off. The value Cam_MT_Length is the amount of bytes and is calculated as
follows: Amount of cams multiplied by six.
Offset_Length is the amount of bytes of the offset parameters, always starting at zero and ending
at the address 10 in this example.
Explanation:
Type
Length
BOOL
1 bit
BYTE
8 bits
WORD
2 bytes
DWORD
4 bytes