DEUTSCH
INDUSTRIAL PRODUCTS DIVISION
3850 Industrial Avenue
•
Hemet, CA 92545
Title Drawing
Number
INSTRUCTION GUIDE FOR DTT-16-02
0425-058-0000
Revision Letter:
A
Engineering Order Number:
P19060
Page
2
of
3
I N F O R M A T I O N
7. CALIBRATION
Table 2.
*Use conductor type per SAE J1128 AND ISO 6722(Metric)
Cavity Wire*
Conductor
Height (1)
Conductor
Width
Insulation
Height
Insulation
Width
A
1.0 mm
2
16 AWG
1.5 mm
2
.057-.067
.058-.068
.060-.070
.110-.115
.110-.115
.110-.115
.090-.100
.094-.106
.100-.110
.090-.096
.092-.098
.093-.099
B
16 AWG (GXL)
1.5 mm
2
12 AWG
.053-.064
.054-.065
.065-.075
.108-.113
.108-.113
.110-.115
.102-.112
.104-.112
.115-.125
.100-.112
.100-.109
.115-.125
Note: check tool calibration values after 5,000 crimps (or 6 months). Visually inspect for loose
hardware and broken or missing parts.
(1)
Measure conductor height with a blade and point micrometer to prevent false readings
which include crimp flash (burr).