7. CALIBRATION

  

 

 

 

Table 2. 

*Use conductor type per SAE J1128 AND ISO 6722(Metric) 

Cavity Wire* 

Conductor 

Height (1) 

Conductor 

Width 

Insulation 

Height 

Insulation 

Width 

1.0 mm

16 AWG 
1.5 mm

2

 

.057-.067 
.058-.068 
.060-.070 

.110-.115 
.110-.115 
.110-.115 

.090-.100 
.094-.106 
.100-.110 

.090-.096 
.092-.098 
.093-.099 

16 AWG (GXL) 

1.5 mm

12 AWG

 

.053-.064 
.054-.065 
.065-.075 

.108-.113 
.108-.113 
.110-.115 

.102-.112 
.104-.112 
.115-.125 

.100-.112 
.100-.109 
.115-.125 

Note: check tool calibration values after 5,000 crimps (or 6 months). Visually inspect for loose 
hardware and broken or missing parts.  
 

(1)    

Measure conductor height with a blade and point micrometer to prevent false readings 

        which include crimp flash (burr). 
 

 

 

 
 
 
 
 
 
 

 
 