background image

 

 22

 

 

 

Table 12:  Parts List - With variable speed motor ECM 

Item

Part

Description

Comments

1

B03775

HEAT EXCHANGER ASSEMBLY

Heat exchanger only

2

B03761

FLOOR ASSEMBLY

3

B03746

WIRE CHANNEL, INTERIOR

4

B03758

LOWER BLOWER DIVIDER ASSEMBLY

Panel, 3 gaskets and filter rack included

5

B03745

SIDE BAFFLE

6

B03754-02

LEFT SIDE PANEL ASSEMBLY

Panel, insulation, baffle and filter rack included

7

B03755-02

LEFT SIDE PANEL INSULATION

8

B03335-03

ELECTRICAL KIT, BVSO INTERIOR

9

B03741-02

LEFT ANGLE FILTER RACK

10

B03740

LEFT SIDE FILTER RACK

11

B03742

REAR FILTER RACK

12

Z04F014

PAPER FILTER 20 X 24 X 1

13

B03718-01

REMPLACEMENT SOUND TRAP ASSEMBLY

2 sections included

14

B03756

BLOWER DOOR ASSEMBLY

Door, handle and label included

15

Z99F050

HANDLE, RECESSED BLACK

16

B03764

REAR FILTER DOOR ASSEMBLY

17

F07O001

HEX FLANGE NUT 3/8-16NC LAITON

18

B01747

FLUE OUTLET FLANGE, 6" DIA.

19

B00205

GASKET, SMOKE PIPE COVER

20

B03757

TOP REAR PANEL ASSEMBLY

Panel and label included

21

J06L002

SEAL STRIP DIA 1/8" DIA X 25'

22

B03751

OUTLET PROTECTOR

23

B03734

TOP DIVIDER

24

B03741-01

RIGHT ANGLE FILTER RACK

25

B03754-01

RIGHT SIDE PANEL ASSEMBLY

Panel, insulation, baffle and filter rack included

26

B03755-01

RIGHT SIDE PANEL INSULATION

27

B03739

RIGHT SIDE FILTER RACK

28

B03735

ELECTRICAL BOX SPACER

29

B03737

ELECTRICAL BOX

30

R02R009

HIGH LIMIT L195-20F, 7.00 in.

31

B03743

ELECTRICAL BOX COVER

Panel only

32

B03118-01

ELECTRICAL KIT, BVSO EXTERIOR

33

F06F015

ZINC WASHER 1 7/16"

34

Z99F061

SIGHT GLASS FOR HEAT EXCHANGER

35

Z06G001

BLOCKED VENT SHUT-OFF BVSO-225

36

B03675

GASKET, SMOKE OUTLET 

37

B03765

CLEAN OUT ASSEMBLY

Item #36 included

38

B03762

PROTECTION COVER ASSEMBLY

Cover and labels included

39

F07F011

HEX NUT 3/8-16NC ZINC

40

B03567-01

BAFFLE

One baffle uncluded

41

B03747

BURNER WIRE CHANEL

42

B03748

WIRE CHANEL

43

L04I010

STRAIN REL. BUSHING 

44

B03759

FRONT PANEL ASSEMBLY

Panel and insulation uncluded

45

B03760

FRONT PANEL INSULATION

46

B03720-05

BLOWER 120-10T DD 0,50PP

Housing, wheel and label included

47

B03787-02

REPLACEMENT BLOWER ASSEMBLY

Blower, motor and capacitor included

48

B01756

BLOWER SUPPORT

49

B01889

MOTOR MOUNT ASSEMBLY

Legs, band and hardware included

50

B03813-06

MOTOR 1 HP ECM 2.3

51

B03242-02

ELECTRONIC KIT

52

B03790-01

ELECTRIC KIT

53

B03555

THERMO DISK PROTECTOR

54

B03465

ELECTRICAL KIT (BOARD)

55

R99G003

ELECTRONIC BOARD 1168

56

L01F009

TRANSFORMER 120-24 Volts, 40VA

57

B03141

INDUCTOR

58

L01G009

CONTROL CARD FUSE - 3 AMPS

VENT TERMINAL KIT 5''

For sealed combustion

5" INSULATED FLEX VENT 10ft
5" INSULATED FLEX VENT 15ft

5" INSULATED FLEX VENT 20ft

For sealed combustion (B02551-08)

BECKETT NX BURNER (0.75-60B NOZZLE)

RIELLO 40-F5 BURNER (0.75-70A NOZZLE)

RIELLO 40-BF5 BURNER (0.75-70A NOZZLE)

For sealed combustion

ACCESSORIES

VTK-65

VTK-3

KLAVT0201DET

IFV-515

N01F056

KLABR0601RLO

N01F053

KLABR0501RLO

N01J053

KLABR0301BEC

IFV-5-8 / KLAFV0301DET

IFV-520

IFV-5-20

KLAFV0401DET

IFV-510

 

B50096C

Содержание AMT154SDMA

Страница 1: ...ke Qu bec www dettson ca Attention Do not tamper with the unit or its controls Call a qualified service technician INSTALLER SERVICE TECHNICIAN USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION...

Страница 2: ...ply air Temperature Rise Test 10 3 3 8 Limit Control Check 10 3 3 9 Restart after burner failure 10 4 MAINTENANCE 10 4 1 CLEANING THE HEAT EXCHANGER 10 4 2 CLEANING THE BLOCKED VENT SHUT OFF DEVICE BV...

Страница 3: ...formation such as the model and serial numbers of the furnace WARNING Installations and repairs performed by unqualified persons can result in hazards to them and to others Installations must conform...

Страница 4: ...re the ambient and return air temperatures are above 15 C 60 F In addition the furnace should be installed as closely as possible to the vent so that the connections are direct and kept to a minimum T...

Страница 5: ...ired for Riello burners Refer to the burner control instruction manual and markings for proper adjustment of the post purge delay 2 5 VENTING WARNING Poisonous carbon monoxide gas hazard Never install...

Страница 6: ...equate supply of combustion air It is common practice to assume that older homes have sufficient infiltration to accommodate the combustion air requirement for the furnace However home improvements su...

Страница 7: ...ated the return air must be sealed and also be directed to the space other than where the furnace is located 2 9 1 Air filter A properly sized air filter must be installed on the return air side of th...

Страница 8: ...heating or air conditioning mode This signal can be used to activate an electronic air cleaner that is not equipped with an air flow switch If the cleaner is equipped with an air flow switch the S te...

Страница 9: ...of the oil piping and pump Slowly close and tighten the bleed screw Once closed the flame will light up 3 3 2 Pressure adjustment The oil pressure must be adjusted according to the Technical Specifica...

Страница 10: ...burner should restart after a few minutes The time required for the restart also depends on the adjustment of the blower OFF delay 3 3 9 Restart after burner failure 1 Set the thermostat lower than r...

Страница 11: ...uction inside the heat transfer tube 7 Re mount lock and fasten the control box with the 2 screws removed in step 4 8 Re attach the assembly cover with the screws removed in step 2 9 Re establish powe...

Страница 12: ...vice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Am...

Страница 13: ...n 87 5 86 2 87 5 86 2 Volts Hertz Phase Rated current Amps Minimum ampacity for wire sizing Amps Max fuse size Amps Control transformer VA External control power available Heating VA Cooling VA Heatin...

Страница 14: ...Time ShortRun On Delay CFM Level Time Off Delay CFM Level Time A 1 OFF 2 OFF 0 90 13 45 sec 44 30 sec 38 3 min B 1 ON 2 OFF 1 10 13 30 sec 44 30 sec 38 3 min C 1 OFF 2 ON 1 10 13 30 sec 50 30 sec 38...

Страница 15: ...WITH AIR FILTER Table 10 Minimum clearances from combustible material LOCATION APPLICATION CLEARANCES combustible materials RECOMMANDED ACCESS FOR SERVICE FURNACE 2 54 cm 1 0 6 m 24 SUPPLY PLENUM WIT...

Страница 16: ...16 Figure 7 Furnace Dimensions...

Страница 17: ...17 Figure 8 Wiring Diagram 4 Speed Motor PSC...

Страница 18: ...18 Figure 9 Wiring Diagram Variable Speed Motor ECM...

Страница 19: ...19 Figure 10 Parts List With 4 Speed motor PSC B50095B...

Страница 20: ...TERIOR 33 F06F015 ZINC WASHER 1 7 16 34 Z99F061 SIGHT GLASS FOR HEAT EXCHANGER 35 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 36 B03675 GASKET SMOKE OUTLET 37 B03765 CLEAN OUT ASSEMBLY Item 36 included 38...

Страница 21: ...21 Figure 11 Parts List With variable speed motor ECM B50096C...

Страница 22: ...ELECTRICAL BOX COVER Panel only 32 B03118 01 ELECTRICAL KIT BVSO EXTERIOR 33 F06F015 ZINC WASHER 1 7 16 34 Z99F061 SIGHT GLASS FOR HEAT EXCHANGER 35 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 36 B03675 G...