SAFETY CONSIDERATIONS

 

Improper 

installation, 

adjustment, 

alteration, 

service, 

maintenance, or use can cause explosion, fire, electrical shock, or 

other  conditions  which  may  cause  death,  personal  injury,  or 

property damage. Consult a qualified installer, service agency, or 

your  distributor  or  branch  for  information  or  assistance.  The 

qualified  installer  or  agency  must  use  factory-authorized  kits  or 
accessories  when  modifying this product.  Refer to the individual 

instructions packaged with the kits or accessories when installing.  
Follow all safety codes. Wear safety glasses, protective clothing, 
and  work  gloves.  Use  quenching  cloth  for  brazing  operations. 
Have  fire  extinguisher  available.  Read  these  instructions 
thoroughly and follow all warnings or cautions included in literature 
and attached to the unit. Consult local building codes, the current 
editions of the National Electrical Code (NEC) NFPA-70.

  

In Canada refer to the current editions of the Canadian Electrical 
Code CSA C22.1 Recognize safety information.  

This is the safety-alert symbol 

. When you see this symbol on 

the unit and in instructions or manuals, be alert to the potential for 
personal  injury.  Understand  these  signal  words; 

DANGER, 

WARNING, 

and 

CAUTION

. These words are used with the safety-

alert

 

symbol. 

DANGER 

identifies the most serious hazards which 

will

 result in severe personal injury or death. 

WARNING

 signifies 

hazards which 

could

 result in personal injury or death. 

CAUTION

 

is  used  to  identify  unsafe  practices  which 

may

  result  in  minor 

personal injury or product and property damage. 

NOTE

 is used to 

highlight  suggestions  which 

will

  result  in  enhanced  installation, 

reliability or operation. 

TABLE OF CONTENTS

General Information/Installation .................................... 2 
Installation..................................................................... 2 
Vertical/Horizontal Installation ...................................... 3 
Ductwork Connection .................................................... 4 
Filter Installation ............................................................ 4 
Electrical Connection ..................................................... 4 
Blower Performance ...................................................... 8 
Sequence of Operation ................................................ 10 
Wiring Diagram ............................................................ 11 
Replacement Parts ....................................................... 12

 

   

WARNING

 

ELECTRICAL SHOCK HAZARD 

Failure  to  turn  off  electric  power  could  result  in 
personal injury or death. 

Before  installing  or  servicing  system,  turn  off  main 
power to  the  system.  There may be  more  than one 
disconnect switch, including accessory heater(s). 

 
 
 

 
 
 

INSTALLATION INSTRUCTIONS 

Air Handler (Electric furnace) 

AHF080014, AHF120017, AHF160021, AHF200024 

Содержание AHF080014

Страница 1: ...Electrical Code CSA C22 1 Recognize safety information This is the safety alert symbol When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injur...

Страница 2: ...approved heaters electric heat accessory models EHIA only Heaters that are not factory approved could cause damage which would not be covered under the equipment warranty CAUTION CUT HAZARD Failure t...

Страница 3: ...recommendations NOTE Local codes may limit application of systems without a ducted return to single story dwellings HORIZONTAL LEFT AND RIGHT INSTALLATIONS The air handler cabinets can be installed in...

Страница 4: ...o Figure 6 All electrical work MUST conform with the requirements of local codes and ordinances and the National Electrical Code NFPA 70 current edition The low voltage transformer and the fan control...

Страница 5: ...ews 3 Connect the 9 pin plug from No Heat Kit wiring into the receptacle that attaches to fan control board 4 Connect ground wire to unit ground lug 5 Connect 208 230V power lead from field disconnect...

Страница 6: ...2 9 3 6 15 2 14 105 32 1 14 230 AHF16 208 1 60 Single 1 2 2 9 3 6 15 2 14 105 32 1 14 230 AHF20 208 1 60 Single 3 4 6 0 7 5 15 2 14 90 27 1 14 230 Figure 8 Wiring Layout Air Conditioning Unit Cooling...

Страница 7: ...r Single Phase EHIA05KB KN EHIA15KB EHIA25KB10 EHIA07KB KN EHIA20KB EHIA10KB KN EHIA25KB EHIA15KB EHIA20KB EHIA25KB Three Phase EHIA10HB EHIA10HB EHIA20HB EHIA15HB EHIA15HB EHIA25HB EHIA20HB EHIA20HB...

Страница 8: ...lectric heat Deduct heater static shown in heater static table Deduct coil static See Coil Specification Sheet Deduct 20 in wc 50 Pa for Downflow Subbase Kit Table 4 Airflow is blower only no coil att...

Страница 9: ...0 02 0 02 0 03 0 04 0 04 1900 0 01 0 02 0 02 0 03 0 04 0 05 2000 0 01 0 02 0 02 0 03 0 04 0 05 ACCESSORIES ELECTRIC AIR CLEANER The Electronic Air Cleaner may be connected to AHF as shown in Figure 1...

Страница 10: ...en call is satisfied Y drops out and there is a 90 second TDR before indoor fan relay opens D HEAT PUMP HEATING WITH AUXILIARY ELECTRIC HEAT Cooling Mode Same operation as above in Heat Pump Cooling M...

Страница 11: ...INSTALLATION INSTRUCTIONS AIR HANDLER AHF X40159 Rev E Specifications subject to change without notice 11 WIRING DIAGRAM...

Страница 12: ...RAPPER 9 PANEL TOP ASS Y 10 LEFT SIDE WRAPPER 7 SIDE BLOWER DECK 8 REAR BLOWER DECK 1 BLOWER DOOR ASS Y 6 FRONT BLOWER DECK DETTSON INDUSTRIES INC DETTSON COM ITEM NO CURRENT PART DESCRIPTION MF080014...

Отзывы: