GAVIN-6C Instruction Manual
- 23 -
EPA
: EPA (end point adjustment) is used to adjust the end point. The larger
the value is, the larger the servo travel is when move the stick. Values: 0~100.
The default is
100
.
EXP
: It is used to set the exponent of the curve. Offer a servo travel that is not
directly proportional to the stick travel. The control response is milder below
half-stick, but becomes increasing stronger as stick travel approaches 100%.
The larger the value is, the milder below half-stick. Values: 0~50. The default
is
0
. When the value is set to
0
, the servo travel is proportional to the stick
travel.
LEVEL
: It is used to move up or down the curve.
RESET
: It is used to set the curve to initial value.
1~9
: It is used to set the value of a specific point. The servo position can be
set independently for a maximum of 9 point positions.
Throttle Curve [THR Curve]
This function is used to adjust throttle servo operation in response to throttle stick
operation. The servo position can be set independently for a maximum of 9 point
positions.
For airplane / multicopter
In the
Model Parameter
menu, press
UP
or
DOWN
key to select
THR Curve
,
and then press
ENT
key to enter the
NORM THR Curve
setting interface.
NORM THR Curve
EPA: +100
EXP: 0
LEVEL
RESET
1
:
0.0
2
:
12.5
3
:
25.0
4
:
37.5
5
:
50.0
6
:
62.5
For helicopter
You can set throttle curve for the helicopter's
NORM
(normal) and
ACR