12
DSCS-9/10
Series
3.0
Installation
•
Heater Mounting
•
Optional Mounting Kit
Heater Mounting
The heater shall be mounted in a fixed position attached from a structure that can evenly support the total
force and weight of the heater. The mounting means shall be independent of the gas and electrical supply
line. All hangars and bracket material shall be of noncombustible construction. Examples of suitable
material include, but are not limited to, steel channel, steel tubing, threaded rod, or field fabricated hangers
that are adequate to bear the load. In some cases, the heater may need to be isolated from vibration with
the use of vibration isolating devices.
The heater must be level from side to side and can be set at an angle between 0° and 30° from horizontal.
Optional Mounting Kit
Optional adjustable mounting kits and brackets are available for the patio heater. When utilizing adjustable
mounting kits and brackets, refer to the insert that is packaged with these accessories for complete
installation instructions.
WARNING
!
Improper suspension of the infrared heater may result in collapse and persons being
crushed. Always suspend from a permanent part of the building structure that can support
the total force and weight of the heater.
Failure to maintain minimum clearance to combustibles may result in fire and/or explosion,
property damage, serious injury or death. Always maintain minimum clearances and post
signs or provided tags (F/N: LL001) where needed. Signs should state the hazards for the
particular application and be legible for the building occupants. Consult the factory or a
factory representative for additional information on signage compliance.
WARNING
!
!
Conditions such as wind drafts or other variables can cause movement of the heater and
may require it to be rigidly mounted. Avoid excessive movement and/or vibration of the
gas connection by rigidly mounting the heater.