DDEC IV TESTING
Check VPOD Output Pressure
Follow these steps to check the VPOD input and output pressure:
NOTE:
Listen for air leaks at the VPOD during the test.
PERSONAL INJURY
To avoid injury from the sudden release of a high-pressure
hose connection, wear a face shield or goggles.
1. Disconnect the air hoses from the EGR and VNT (Variable Nozzle Turbine) actuators.
2. Install pressure gauges (accurate to within 1.4 kPa [0.2 psi]) at the outlet of the EGR and
VNT hoses. (Use two gauges, or test separately.)
3. Using the DDDL/DDR, activate PWM #2 (EGR) and PWM #4 (VNT) duty cycles and
monitor the output pressure from the VPOD.
4. Test: activating 11% duty cycle: Pressure = 106-134 kPa (15.4-19.4 psi). Go to steps
5[a] and 5[b].
5-10
All information subject to change without notice.
(Rev. June 2005)
7SE60 0506
Copyright © 2005 DETROIT DIESEL CORPORATION