COOLING SYSTEM
Figure 7-6
Rapid Warm-up with Integral Top Tank
7.5.2
CONVENTIONAL COOLING SYSTEM
The conventional cooling system is
fi
lled directly through the radiator core. It has low coolant
fl
ow through the core during closed thermostat operation from small air bleeds located in the
thermostat or in the thermostat housing. This type of system may experience slow warm-up or
inability to maintain minimum operating temperatures during cold ambient operations. Detroit
Diesel will not approve a conventional cooling system for the MBE4000.
7.5.3
AUXILIARY AIR-COOLED COOLER CORES
Heat exchangers in addition to jacket water and charge air cooler radiators are quite often part of
the total cooling system. Heat exchangers such as air-to-oil, air-to-air, oil-to-air, or others are
to be used and mounted either in front of the radiator or behind it. If auxiliary coolers are used,
greater restriction of air
fl
ow and increased heat load must be considered.
NOTE:
Provide access to the areas between the cores for cleaning purposes.
7.5.4
COOLANT HEATERS
Cold weather operation often requires the use of coolant heaters. Information on coolant heaters
can be obtained from DDC Application Engineering.
7-10
All information subject to change without notice.
(Rev. 03/06)
7SA250 0603