MBE 900 ENGINE 2007 OPERATOR'S GUIDE
EYE INJURY
To avoid injury from
fl
ying debris
when using compressed air, wear
adequate eye protection (face
shield or safety goggles) and do
not exceed 276 kPa (40 psi) air
pressure.
[c] Apply no more than
140 kPa (20 psi) air pressure
intermittently to help dislodge
sediment buildup in the core.
5. Drain the radiator, and
fl
ush the
radiator until clean water
fl
ows
from the radiator. Remove the
fl
ushing gun.
6. When the coolant has drained,
install the coolant drain plug on
the radiator.
7. Add coolant in the speci
fi
ed
concentration until the maximum
mark on the surge tank is reached.
Coolant system capacity is
listed in Table 11.
Description
Value: L (qt.)
Engine Coolant Capacity (all vehicles) L (Qt.)
Engine capacity
12 (12.7)
Business Class Coolant System Capacity L (Qt.)
Total capacity
23.6 (25)
Antifreeze quantity at 50%
11.8 (12.5)
Antifreeze quantity at 55%
13.1 (13.8)
Table 11
Coolant System Capacity
8. Start the engine and run it for
about one minute at varying
speeds to release air pockets in
the cooling system. Make sure
the heater valve is still open.
Check the coolant level and add
more coolant if necessary.
9. Shut down the engine.
10. Add coolant if necessary.
All information subject to change without notice.
(Rev. 04/08)
85
DDC-SVC-MAN-0040 0704
Copyright © 2008 DETROIT DIESEL CORPORATION
Содержание MBE 900
Страница 1: ......