84
Globetrotter XXL - 11-06 - DET-0047-01
EN
Electrical system
9
Measures:
When the battery alarm comes on, switch off the appliances and com-
pletely charge the living area battery, either by mobile operation or by con-
nection to a 240 V power supply.
9.7.6
Battery capacity alarm for the living area battery
The basic menu appears and the symbol (Fig. 56,1) flashes. The Ah-data and
the "CHARGE!" command are also displayed in the battery menu.
9.7.7
Battery defect message for living area battery
The basic menu appears and the symbol (Fig. 56,1) flashes. The "DEFECT!"
display is also displayed in the battery menu.
9.7.8
Tank menu
When keys are pressed the LCD display is lit automatically.
Calling menu:
Press the tank menu key (Fig. 55,9): The level of the water tank is dis-
played.
Press the tank menu key repeatedly or the "+" key (Fig. 55,4) to call up the
following information in succession:
Filling level of the waste water tank
Filling level of an addition tank (optional)
Various settings can be made in the tank menu.
Switching the water pump
on and off:
Press the tank menu key (Fig. 55,9).
Press the "OK" key (Fig. 55,6) as long as the LCD display is lit.
Switch the water pump on or off by pressing the "OK" key again.
Switching the waste water
tank heater on and off:
Press the tank menu key (Fig. 55,9).
Press the tank menu key again as long as the LCD display is lit.
Press the "OK" key (Fig. 55,6) as long as the LCD display is lit.
Switch the tank heater on or off by pressing the "OK" key again.
9.7.9
Tank alarm
The basic menu appears and the symbols (Fig. 56,15 and 17) flash when the
water tank is empty or the waste water tank is full. Additionally, the corre-
sponding percentage indicator flashes in the tank menu.
Total discharge damages the battery.
If the battery voltage falls below 10.5 V, the battery monitor in the trans-
former/rectifier switches off all of the 12 V appliances, excluding the safety/
drainage valve.
The tank alarm can be switched off, for example, if the water tank is con-
stantly empty from using a direct water supply.
Содержание 2006 Globetrotter XXL
Страница 2: ...Globetrotter XXL 11 06 DET 0047 01EN Instruction manual ...
Страница 6: ...Contents 6 Globetrotter XXL 11 06 DET 0047 01EN ...
Страница 14: ...14 Globetrotter XXL 11 06 DET 0047 01EN Guarantee 1 ...
Страница 18: ...18 Globetrotter XXL 11 06 DET 0047 01EN Introduction 2 ...
Страница 38: ...38 Globetrotter XXL 11 06 DET 0047 01EN Before the journey 4 ...
Страница 42: ...42 Globetrotter XXL 11 06 DET 0047 01EN During the journey 5 ...
Страница 64: ...64 Globetrotter XXL 11 06 DET 0047 01EN Living 7 ...
Страница 72: ...72 Globetrotter XXL 11 06 DET 0047 01EN Gas system 8 ...
Страница 106: ...106 Globetrotter XXL 11 06 DET 0047 01EN Appliances 10 ...
Страница 136: ...136 Globetrotter XXL 11 06 DET 0047 01EN Wheels and tyres 14 ...
Страница 144: ...144 Globetrotter XXL 11 06 DET 0047 01EN Troubleshooting 15 ...