The capacity of a battery is given in ampere hours (Ah). If a battery possesses
a capacity of 80 Ah, then the battery can dispense a current of 1 A for 80 hours
or a current of 2 A for 40 hours.
External influences such as temperature may alter the storage capacity of the
battery.
9.3
12 V power supply
When the vehicle is not connected to the 240 V power supply or the 240 V
power supply is switched off, the living area battery supplies the living area
with 12 V DC. The living area battery has a limited power supply only. For this
reason, electrical appliances such as the radio and the lights should not be
operated for a long time without using the 240 V power supply.
When the vehicle engine is running, the vehicle alternator recharges the living
area battery and the starter battery.
The 12 V power supply can be cut off with the 12 V main switch on the panel.
Depending on the model, the heater, basic light/entrance step and reserve 4
or only the electrical entrance step remain on standby. The refrigerator is then
only operated with 12 V if the vehicle engine is running. This helps to prevent
the living area battery from being run down too quickly.
9.3.1
Living area battery
To disconnect all electrical 12 V appliances from the power supply, set the
battery cut-off switch on the transformer/rectifier to "battery off".
Prior to commencing a journey ensure the living area battery is fully
charged. For this reason charge the living area battery for at least 20 hours
before commencing the journey.
During the trip, use every opportunity to charge the living area battery.
Charge the living area battery for at least 20 hours after the journey.
Charge the battery for at least 20 hours before laying up.
Use the charger module provided on the transformer/rectifier to charge the
living area battery. When charging externally, use a regulated charger that
is suitable for the battery type (a lead acid or dryfill battery) and the capacity
of the living area battery.
For long periods of inactivity (4 weeks or more), either switch off the living
area battery using the battery cut-off switch on the transformer/rectifier, or
recharge it regularly.
When the living area battery is changed, only use batteries of the same
type. A dryfill battery may only be replaced by a dryfill battery.
Before disconnecting or connecting the terminals of the battery, switch off
the vehicle engine as well as the 240 V and 12 V power supplies and all
appliances. Danger of short circuit!
If the starter battery or living area battery are disconnected, do not apply
the ignition. Danger of short circuit!
Take note of the battery manufacturer's users and maintenance instruc-
tions.
Appliances with a maximum of 10 A can be connected to the sockets of the
12 V power supply system.
Содержание 2006 Globetrotter XXL
Страница 2: ...Globetrotter XXL 11 06 DET 0047 01EN Instruction manual ...
Страница 6: ...Contents 6 Globetrotter XXL 11 06 DET 0047 01EN ...
Страница 14: ...14 Globetrotter XXL 11 06 DET 0047 01EN Guarantee 1 ...
Страница 18: ...18 Globetrotter XXL 11 06 DET 0047 01EN Introduction 2 ...
Страница 38: ...38 Globetrotter XXL 11 06 DET 0047 01EN Before the journey 4 ...
Страница 42: ...42 Globetrotter XXL 11 06 DET 0047 01EN During the journey 5 ...
Страница 64: ...64 Globetrotter XXL 11 06 DET 0047 01EN Living 7 ...
Страница 72: ...72 Globetrotter XXL 11 06 DET 0047 01EN Gas system 8 ...
Страница 106: ...106 Globetrotter XXL 11 06 DET 0047 01EN Appliances 10 ...
Страница 136: ...136 Globetrotter XXL 11 06 DET 0047 01EN Wheels and tyres 14 ...
Страница 144: ...144 Globetrotter XXL 11 06 DET 0047 01EN Troubleshooting 15 ...