MAX BYPASS TIME SETTINGS:
5 min 10 min 20 min 40 min
DETAIL B
To by-pass for
service, pull post out
Turn access control
key CCW
DETAIL C
TAMPER SWITCH ASSY
OR OR OR
O
N
O
N
O
N
O
N
O
N
O
N
O
N
O
N
O
N
O
N
4. ENCLOSURE MOUNTING
:
Prep surface of wall for mounting Exit Alarm enclosure. Enclosure is designed for all wires to be routed through grommet in rear
hole. Route wires from transformer and magnetic switch through rear hole
BEFORE
mounting enclosure.
Mount enclosure using mounting screws supplied in hardware kit.
Mounting kit options:
Option 1 - #10 sheet metal screws and #10 plastic anchors
Option 2 - #10 self-drilling screws
NOTE:
Enclosure must be earth grounded per NEC requirements.
5. ENCLOSURE INSTALLATION
:
Connect magnetic switch wires to PC board located on enclosure door. (See FIG 3 and DETAIL A). Examples shown are for
Detex supplied magnetic switches. Transformers and magnetic switches are required and can be purchased separately.
Connect power wires to the two place terminal block located on lower left corner of power board. Wires are not polarity sensitive
(Fig. 3).
By-Pass time is factory set for 5 minutes. See detail B above for additional By-Pass time options.
To By-Pass for service, extend plunger on tamper switch. (See DETAIL C)
Insert access control key into mortise cylinder on front side of hinged panel.
Install battery (supplied with unit). Remove plastic protectors from the polarity sensitive battery terminals. Alarm will sound if
magnetic switch is not closed and tamper switch plunger is not extended.
Plug wall mounted transformer into wall outlet.
Turn access control key counterclockwise (CCW) 1/4 turn and HOLD for 5 seconds LIGHT BAR METER will turn OFF and
ALARM is reset. Close hinged panel and secure cover lock. Alarm will sound. To silence alarm, rotate access control key CCW.
The single RED LED located next to light meter bar will turn ON indicating device is powered and in the armed mode. Alarm will
sound if magnetic contact switch on door is opened. To silence alarm close magnetic contact switch on door and turn control
key CCW.