INSTALLATION INSTRUCTIONS FOR DETEX EAX-3500 ALARM

Detex Corporation,  302 Detex Drive,  New Braunfels,  Texas  78130-3045

(830)629-2900  /  1-800-729-3839  /  Fax (830)620-6711

E-MAIL: [email protected]               INTERNET: www.detex.com

103140  March 3, 2011

ACTIVATE

TIMED BY-PASS

-3500

RESET

TO ADD ADDITIONAL BY-PASS TIME:

1) Insert key and rotate CCW until green LED turns off.

    Release key.

2) Press "ACTIVATE TIMED BY-PASS" button. Light

    bar meter illuminates gradually as more By-Pass

    time is added.

NOTE: If By-Pass time expires while door is open,

           alarm will sound.

TO SILENCE ALARM:

 Close door, insert and rotate

           key CCW.

TO ACTIVATE TIMED BY-PASS:

1) Rotate key counterclockwise (CCW), light bar meter

    flashes, then release key.

2) To add By-Pass time, press "ACTIVATE TIMED

    BY-PASS" button. Light bar illuminates gradually

    as more bypass time is added.

3) Release button. Single green LED turns ON

    indicating By-Pass time is set.

4) Remove key and prop open door.

NOTE: Alarm automatically arms and resets if door

            closes before time expires.

103140   Page 1

Содержание EAX-3500

Страница 1: ...ght bar meter illuminates gradually as more By Pass time is added NOTE If By Pass time expires while door is open alarm will sound TO SILENCE ALARM Close door insert and rotate key CCW TO ACTIVATE TIMED BY PASS 1 Rotate key counterclockwise CCW light bar meter flashes then release key 2 To add By Pass time press ACTIVATE TIMED BY PASS button Light bar illuminates gradually as more bypass time is a...

Страница 2: ... 10 x 1 10 x 1 PPH PPH Tools Required Pencil Metal Applications All other Applications Drill Bit Fastener Table Comments w Anchors EAX 3500 Installation and Usage Guide Display Board p n 103943 Cover Lock Key 102966 Bracket p n 103970 p n 100783 Cam Assembly p n 102680 p n 102627 15 2 pls Battery Strap p n 103963 Modular Cable p n 104017 5 12V Battery p n 103952 Power Supply Board p n 103941 Tampe...

Страница 3: ...nt MS2049S Option connections Magnetic switch White Red NOT Used Black Magnetic Switch Surface Mount DISPLAY BOARD POWER BOARD 2 MAGNETIC SWITCH INSTALLATION Install magnetic contact switch onto door using magnetic switch instructions For wire requirements see Manufacture s Recommendation Chart Route wires to Exit Alarm location Magnetic Contact Switch Within 6 feet 2 conductor cable 22AWG 20 feet...

Страница 4: ...onnect power wires to the two place terminal block located on lower left corner of power board Wires are not polarity sensitive Fig 3 By Pass time is factory set for 5 minutes See detail B above for additional By Pass time options To By Pass for service extend plunger on tamper switch See DETAIL C Insert access control key into mortise cylinder on front side of hinged panel Install battery supplie...

Страница 5: ... release Then press the Activate Timed By Pass button Make sure door is fully closed Make sure wiring to the magnetic switch is not damaged or cut Check AC power to the device and that building power is present at the outlet Make sure optional plug in transformer is plugged in and the holding screw installed Check for damaged wiring between the transformer and the EAX 3500 The battery should be re...

Отзывы: