104889 Page 7
DOOR PROP OPERATIONS:
The door prop function is selected by setting SWITCH A to the 'OFF'
position. To arm the system, close the door and turn the key CCW to the 'ON'
position. The red LED will flash twice indicating that the device is now armed. If the door is opened,
the device will begin a timing countdown according to the selected amount of time (15 seconds default).
If the
Status Indicator
(switch B) is 'ON', the red LED will blink every second during the countdown. If the door is not closed
before the door prop time runs out, the alarm sounds and the red LED flashes. Closing the door will silence the alarm and
rearm the unit. To change the door prop timing, see the section
Changing Door Prop Timing
.
DOOR CHIME OPERATIONS:
The door chime function is selected by setting SWITCH A to the 'ON' position.
To arm the system, close the door and turn the key CCW to the 'ON' position. The red LED will flash twice indicating
that the device is now armed. If the door is opened, the device sounds a series of siren chirps lasting
five seconds. No other action is taken until the door is closed and the unit rearms.
DISARMING:
To turn off the alarm or disarm the system, turn the key CW to the 2 o'clock position.
TROUBLESHOOTING: If the unit does not arm, the magnet may need to be re-aligned or shimmed closer to
the EAX-300. If the unit fails to operate correctly, restart the device by removing the battery for approximately
five seconds.
LOW BATTERY ALERT:
Simultaneous siren chirps and red LED flashes occur at 45 second intervals when
battery reaches approximately 7 volts. Cut the
LV Opt
jumper if low battery alert is not desired.
STATUS INDICATOR:
With the Status indicator (SWITCH B) 'ON': red LED flashes every six seconds
when armed; green LED flashes every six seconds when disarmed.
LV Opt jumper
(under Switch A)
LV opt
JP1
OKC switch
shown closed
OKC
switch
released
Switch lever
represents
key in 'OFF'
position
Switch lever
represents
key in 'ON'
position
OUTSIDE
KEY
CONTROL
Rotate lever
to left stop
CHANGING DOOR PROP TIMING:
Note: *Device must be magnet handed. *LED indications will flash a total
of 3 times before the timing is changed.
Step 1: Turn the key CW to the 'OFF' position, remove the unit from the door and disconnect the battery.
Step 2: Turn the key CCW to the 'ON'
position.
Step 3: While holding the OKC lever in the closed position (by rotating lever to the left stop), reconnect the battery.
The device will chirp the siren once and the LEDs will flash the currently selected door prop time (See Table B).
Release the OKC switch lever and turn the key to the 'OFF' position.