background image

101256 Page 14 

Advantex EA Troubleshooting Tips for Default Setting 

 

 Problem 

Probable Cause 

Action 

When unit is armed, red 
LED flashes twice, green 
LED is on for 15 seconds, 
but the unit does not give 
three beeps after the green 
LED goes off. 
 

The actuator is sticking to 
the micro switch.  
 
 
 
 

Call Detex. 
1-800-729-3839 

No LED activity when 
key is turned ccw to 
armed position. 

Dead or weak battery. 
 
 
 
Battery not secured to 
connector correctly. 
 
Battery connector or wires 
damaged. 
 
No AC power. 

Install new battery, LED’s 
should flash and the siren 
beep once. 
 
Secure battery correctly. 
 
 
Call Detex. 
1-800-729-3839 
 
Verify power from 
transformer and check for 
correct voltage at connector 
P2. 

AC powered unit gives a 
low battery indication.  

Battery not installed. 
 

Install battery. 
If battery is not desired, 
disconnect power and  
slide the ‘Dis Lo Bat IND’ 
switch to ‘ON’ position. 
 

LED’s do not flash to 
indicate armed or 
disarmed status. 
 
 

Status indicator switch in off 
position. 

Remove power from unit.  
Slide ‘Status indicator’ 
switch to ‘ON’ position.  
Reinstall power. 
 

Technical Support 1-800-729-3839 