Advantex EA Troubleshooting Tips for Default Setting
Problem
Probable Cause
Action
When unit is armed, red
LED flashes twice, green
LED is on for 15 seconds,
but the unit does not give
three beeps after the green
LED goes off.
The actuator is sticking to
the micro switch.
Call Detex.
1-800-729-3839
No LED activity when
key is turned ccw to
armed position.
Dead or weak battery.
Battery not secured to
connector correctly.
Battery connector or wires
damaged.
No AC power.
Install new battery, LED’s
should flash and the siren
beep once.
Secure battery correctly.
Call Detex.
1-800-729-3839
Verify power from
transformer and check for
correct voltage at connector
P2.
AC powered unit gives a
low battery indication.
Battery not installed.
Install battery.
If battery is not desired,
disconnect power and
slide the ‘Dis Lo Bat IND’
switch to ‘ON’ position.
LED’s do not flash to
indicate armed or
disarmed status.
Status indicator switch in off
position.
Remove power from unit.
Slide ‘Status indicator’
switch to ‘ON’ position.
Reinstall power.