Indicator turns green when operator

signal is active

Terminals are connected

to a SPDT dry contact relay

Terminal 14 is common

Terminal 13 is normally closed

Terminal 15 is normally open

Door Operator Signal and Indicator

PWA 102879 Electronic Latch Retraction Controller

I/O and Quick Reference Operating Information

Door Operator Signal Delay

Door operator signal is triggered

after latch retraction and time is

adjustable from 0.5 to 3 seconds.

Operator signal delay time

differential is adjusted by R21

Turn CW to increase delay time

Use a normally open dry contact switch,

close to operate. Terminals are electrically

equivalent.

Important: Observe Polarity when connecting

output wires

Door 2 Out

Indicator turns red

when door is active

Door Outputs

D

oo

r 2

 P

ow

er

+

9

Two Door

Systems Only

12

Door 1 Out

J2

11

+

10

-

J3

D

oo

r 1

 P

ow

er

-

Door Differential Delay

Important: Differential time is

factory set and should not require

adjustment. Adjust for special

circumstances only. Door actuation

time differential is adjusted by R5.

Turn CW to increase differential time.

R5

       DETEX Model 81-800

  Connection Diagram and Instructions

The 81-800 is a regulated and filtered power supply.

It has a selectable output voltage of either 12 or 24 volts DC.

For Detex systems always select 24 volts DC.

Refer to the drawing of the power supply/controller for connections

and adjustments.  All connections and adjustment must be made with

the power supply de-energized 

AND

 main power switch (item 3) in

the OFF position.

1: Main power connection. Observe correct terminal connections. Color

code requires connections made per NFPA72. Leave circuit

de-energized while installing and servicing unit.

2: Fire loop control. The fire loop control is bypassed with a factory

jumper. This allows the unit to operate independently and does not

require any external connections to operate.  If connections to the

building fire alarm system are required, remove jumper plate 

A

 between

the (-) and (C)terminals. Connect the two wires from the building fire

system to these terminals. The power supply will operate normally as

long as the connection between the (-) and (C) is maintained. When the

building fire alarm system opens the circuit, the power supply

de-energizes the output voltage. Fire loop uses 24 volt sense voltage.

Door Hold Select

Latch retraction hold time is adjusted by R13

Turn CW to increase hold time up to 30

seconds

Q6

Input 3

R13

Increase

Hold

Time

P

W

A

 1

02

87

9

D11

7      8

Input 3

5      6

Typical Single Door

Installation

81-800

Diff.

Adj.

Model 81-800 Regulated Power Supply

Green when power is good

Power Indicator

3  4

Input 1

5  6

Input 2

7  8

Input 3

N.O.

Switch

Input 2

Control Inputs

5     6

3     4

N.O.

Switch

Input 1

N.O.

Switch

Input 3

7     8

Optional 12 Volt Supply Module

Optional 12 volt supply

module plugs onto P1

and P2. Plug is keyed for

alignment, do not force.

Order DETEX catalog

number: 12M

R21

Door Signal

Delay Adjust

300 mA max

P1

P2

Label P/N 103521-2 Rev 01 05/25/05

13

15

14

N.O.

com

N.C.

Door Signal

101339  Page 2

Содержание 800 Series

Страница 1: ...ion 302 Detex Drive New Braunfels Texas 78130 3045 830 629 2900 1 800 729 3839 Fax 830 620 6711 E MAIL detex detex com INTERNET www detex com 101339 November 16 2011 INSTRUCTIONS FOR 81 800 Owner s Copy 101339 Page 1 ...

Страница 2: ...justment must be made with the power supply de energized AND main power switch item 3 in the OFF position 1 Main power connection Observe correct terminal connections Color code requires connections made per NFPA72 Leave circuit de energized while installing and servicing unit 2 Fire loop control The fire loop control is bypassed with a factory jumper This allows the unit to operate independently ...

Страница 3: ...t the factory and require no adjustment If they need adjustment de energize the unit first 6 Output terminals Outputs 24 volts at 1 amp maximum The output is protected by a PTC thermally resetable fuse element The fuse will reset once the cause of the overload is found and corrected Observe correct polarity when making connections Factory wired to ER control board 7 Optional battery backup connect...

Страница 4: ... 3 J4 is closed 10 Door Hold Delay Adjust This potentiometer adjusts the length of time the latch is held retracted once the input switch is released Turn clockwise to increase the latch hold time up to a maximum of about 30 seconds 11 Output to ER Device This terminal block J2 is connected to the ER power wires Observe correct polarity Red from the ER is positive terminal 11 and black is negative...

Страница 5: ...M12 300 mA max P1 16 Optional 12 Volt Power Module An optional 12 volt power supply module is available where a 12 volt DC source is needed in addition to 24 volts See the kit instructions for more information RECOMMENDED WIRE SIZES WIRE GAUGE MAXIMUM LENGTH OF TWO CONDUCTOR CABLE 20 AWG 10 FEET 18 AWG 40 FEET 16 AWG 60 FEET 14 AWG 100 FEET 101339 Page 5 ...

Отзывы: