SETUP AND INSTALLATION, CONT. 

Placing the Display 

The VET-330WH display has a 7.0 ft (2.1 m) cable to allow it to be placed at a convenient 
position away from the scale base. The included bracket can be used to mount the display 
on a wall or it can be used to place it on a desk or table for easy viewing. 
 

Wall Mounting 

1. 

Choose the location to mount the display on the wall where it can be easily viewed, not 
subject to direct sunlight, and where the keypad is within easy reach of the operator. 

2. 

Using the bracket for a template, place the bracket against the wall and mark the holes 
to mount it. Remove the bracket and drill two (2) 13/64 in (5 mm) holes in the wall for the 
mounting wall anchors. 

Use the mounting bracket as a template to mark holes to drill. 

 

3. 

Insert the wall anchors in the wall until they are flush with 
the wall. 

4. 

Insert the two (2) M3.0x25 screws into the wall anchors, 
and then tighten them until there is approximately 1/8”  
(3 mm) gap between the screw head and the anchor. 

5. 

Place the display in the bracket and install the included enclosure knobs. Adjust the 
angle of the display for the best viewing, and then completely tighten the knobs. 

 

Place the display in the mounting 
bracket and install the enclosure knobs. 

Adjust display for viewing 
angle and completely 
tighten enclosure knobs. 

 

6. 

Place the large end of the slotted holes in the bracket over the screw heads, and gently 
pull down to secure the bracket and display to the wall.  

 

Leave 1/8” (3 mm) gap between 
screw head and wall anchor. 

Содержание VET330WH

Страница 1: ...I MODEL VET 330WH Digital Veterinary and General Purpose Scale Owner s Manual...

Страница 2: ...II...

Страница 3: ...st such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever meas...

Страница 4: ...1961 M045 O1 Rev B y VET 330WH Owner s Manual II...

Страница 5: ...4 Desk Mounting Page 5 AC Power Adapter Page 5 Battery Pack Page 5 Low Battery Indicator Page 5 Battery Charging Page 5 DISPLAY SYMBOLS Page 6 KEY FUNCTIONS Page 7 OPERATION Page 8 CONFIGURATION Page...

Страница 6: ......

Страница 7: ...i Blade input wall plug in UL CUL listed AC power adapter Cardinal P N 6800 1044 Construction Stainless steel Tare 100 of scale capacity Keys HOLD UNIT ON ZERO OFF TARE Operating Environment Temperatu...

Страница 8: ...l from the scale platform display and other components You should have the following components 1 Scale Platform with attached Display 1 Stainless Steel Platform Cover 1 Wall or Desk Display Mounting...

Страница 9: ...knees until you re in a squatting position Never bend at the waist with your legs straight Lifting Scale from Floor to Transport Position 1 Stand close to the scale with your feet 8 to 12 inches apar...

Страница 10: ...2 13 64 in 5 mm holes in the wall for the mounting wall anchors Use the mounting bracket as a template to mark holes to drill 3 Insert the wall anchors in the wall until they are flush with the wall 4...

Страница 11: ...et The scale is now ready for operation Battery Pack The VET 330WH scale uses a 7 2V DC 1200 mA built in rechargeable battery pack Cardinal P N 6800 1067 The VET 330WH can operate for approximately 8...

Страница 12: ...the weight display is at center of zero This symbol is turned on to indicate the battery pack needs to be recharged HOLD The arrow symbol is turned on and will flash after pressing the HOLD key to in...

Страница 13: ...guration Mode press this key to select the menu ON ZERO OFF 1 When the scale is off press and release this key to turn the scale on 2 If the scale is already on press and release this to turn the scal...

Страница 14: ...lay Place the container e g a box pet carrier or travel cage on the scale platform allow the scale to stabilize and then press the TARE key The weight on the scale can be tared zeroed off until the fu...

Страница 15: ...ss the UNIT key to toggle between Enable display will change to 0 or Disable display will change to 4 Press the HOLD key The display will change to 0 5 Proceed to Automatic Shutoff To select lb pounds...

Страница 16: ...should not require changing in most locations If the factory settings do not meet the requirements of your location contact the factory for the value for your location With 9 enable from the function...

Страница 17: ...capacity Remove the weight to clear the error This error can also be displayed if the Zero count is too high Please consult your scale service representative CARE AND MAINTENANCE The heart of the VET...

Страница 18: ...ng for the freight both ways This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does...

Страница 19: ...ction with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or con...

Страница 20: ...30WH Owner s Manual 14 Cardinal Scale Manufacturing Co 102 E Daugherty Webb City MO 64870 USA Ph 417 673 4631 or 1 800 641 2008 Fax 417 673 2153 Technical Support 1 866 254 8261 E mail tech cardet com...

Отзывы: