36
09 / 14
10
Electrical connection
The SILENT is an extractor fan designed
for a single-phase supply, with voltage
and frequency as indicated on the rating
plate of the unit.
The units are manufactured with double
electrical insulation (Class II) and
therefore they do not need an earth
connection.
The electrical cable must enter the
SILENT through the cable entry (4).
The SILENT must be connected to the
electrical supply in accordance with local
wiring regulations.
Once the cable has been introduced
proceed using the electrical wiring
diagram applicable to the selected
model.
SILENT S
For these models, use the following
diagrams:
Fig.3: Switching the extractor through the
light switch.
Fig.4: To switch the fan through an
independent switch.
SILENT T
This model is provided with an adjustable
over-run timer. The timer allows the fan to
continue to operate for the selected
period after the switch has been turned
off (fi g.6).
Fig.5 shows how to connect the fan with
timer utilising the same switch as for the
lighting circuit.
To set the timer, turn the potentiometer
on the printed circuit board as (fig. 7).
- To reduce the “run on” time, turn
anticlockwise (min. 1 minute).
- To increase the “run on” time, turn
clockwise (max: 30 minutes).
SILENT-100 IT
(This version is only available as
SILENT-100)
This model is provided with an adjustable
over-run timer. The timer allows the fan to
continue to operate for the selected
period after the switch has been turned
off (fi g.6).
ATTENTION
: The product also includes
an over-run timer facility that starts the
fan after the first 50 seconds of non-
operation. After these first 50 seconds,
the fan operates automatically.
SILENT HT
IMPORTANT: Do not remove the tape
covering the humidity sensor located
on the reserve of the grille.
Models provided with an electronic
humidistat which can be adjusted from
60% to 90 % RH (Relative Humidity) and
with a timer, adjustable between 1 and 30
minutes.
The desired humidity level and run on
time are selected by means of 8 dip-
switches placed on the printed circuit
board, and easily accessible. Each dip-
switch has two positions [ON (1) and OFF
(0)] which are selected with the small
plastic screwdriver supplied with the fan
(fig.10):
The functions of these dip-switches are:
Содержание SILENT 100 12V
Страница 4: ...Deta Smoke Detector Datasheet 4 ...
Страница 6: ...Deta Optical Detector User Instructions 6 ...
Страница 11: ...Deta Heat Detector User Instruction 11 ...
Страница 12: ...12 ...
Страница 13: ...13 ...
Страница 14: ...14 ...
Страница 16: ...Deta CO Detector User Instructions 16 ...
Страница 21: ...21 Envirovent 100 document ...
Страница 24: ...24 Envirovent 150 document ...
Страница 27: ...27 Envirovent 100 and 150 ...
Страница 28: ...28 SILENT Instruction leaflet 01 14 ...
Страница 29: ...29 Fig 1a Fig 1b 1 2 3 4 5 1 2 3 4 5 6 3 02 14 ...
Страница 30: ...30 03 14 Fig 4 Fig 3 Fig 2 L N L N Ls L N L N Ls 4 ...
Страница 31: ...31 04 14 L N Fig 7 Fig 6 Fig 5 L N Ls L N Ls T min T min A 5 20 30 L N SILENT T SILENT IT SILENT PIR 5 ...
Страница 32: ...32 05 14 Fig 10 Fig 9 Fig 8 L N L N Ls L N L N Ls 2 3 4 1 5 6 7 8 ON 2 2 3 3 4 4 1 1 5 5 6 6 7 7 8 8 ON OFF 6 ...