Appendix A2: Mounting of the DESSALATOR® high-pressure
nozzles
1. Screw the brass fitting onto the high-pressure hose counter-clockwisela all the
way to the
vertical mark
on the outside of the fitting.
2. Place the brass plug in the stainless steel nut and tighten it firmly:
3. Put a little grease on the tip of the stainless steel cone and screw it by placing
it straight in the brass fitting. Stop as soon as the stainless steel thread has
disappeared in the brass nozzle, i.e. about 7 mm of space between the nut and
the brass fitting.
4. Unscrew the nut of the conical adapter. The nozzel is ready for the pipe from
the pump to the membrane. Sheathing is with another pipe is a good idea to
protect it against vibration.
5.
IMPORTANT
: Make sure that the nozzle has not clogged the pipe :
•
Either by blowing into the pipe,
•
Or by inserting a screwdriver to check that the passage is free.
Do not forget to put Loctite or threadlock on the male and female cones when
reassembling.