5) Membrane Block
Ø
The membrane block should preferably be mounted horizontally (on the base or side).
Ø
A vertical position might lead to a yield/output loss over time.
Ø
Fastening is done using self-tapping screws in the stainless steel brackets .
Ø
It is necessary to sheath the pipe connecting the output of the high pressure pump to
the inlet of the membranes
because of the vibrations, which might lead to leaks if
the pipe is attached or in direct contact with something.
Ø
The installation of the high-pressure nozzles must be carried out according to their
assembly instructions (see
Appendix A2
).
Ø
Put some Loctite or threadlock on the 2 male and female cones before tightening.
Ø
Available as an option: 90° elbow high-pressure nozzle for the inlet and outlet of the
membranes .
Stainless steel legs to fix the membrane block
Connection of the high-pressure pump to the inlet of the membrane block
Membrane heads (optional 90° elbow connection for membrane heads)
Hose for the high-pressure water system (supplied)