Operation
EN
12 / 28
06/2020
Press this button during 2 seconds.
Press this button to reach
Configuration
.
Go to
Torque unit
, use the buttons to select the torque unit and validate.
How to set up the Pset
There are 6 pre-defined Psets in the tool.
Parameters are already configured according to the tool characteristics.
Check that the Pset password is disabled.
The green padlock is displayed on the top line.
Go to the main screen.
Press this button during 2 seconds.
Press this button to reach
Pset
.
Use the buttons to navigate, save and validate.
If no action is done, the display returns to the main screen after 15 seconds and the changes will not be saved.
Pressing the trigger at that stage will cancel all modifications done.
Parameter
Description
Thread
Selection of the thread direction of the screw.
CW: when operating in forward, the tool rotates clockwise.
CCW: when operating in forward, the tool rotates counter-
clockwise.
Tightening strategy
Torque control with angle monitoring
or
Angle control with angle monitoring.
Target torque
The torque value to reach.
Target angle
The angle value to reach.
Min./max. torque
Torque values which define the min./max. torque tolerances.
Min./max. angle
Angle values which define the min./max. angle tolerances.
Abort angle
Safety angle value to stop the tool.
Abort torque
Safety torque value to stop the tool.
Start torque
This is the torque value that must be reached to declare the
Pset as started. Below this value, neither result or report will
be generated.
Angle threshold
This is the torque threshold value used to start counting the
angle.
Rundown speed
Speed applied from the start to "Downshift torque".
Downshift torque
Torque value where the speed moves from "Rundown speed"
to "Downshift speed".
Final speed (or Downshift speed)
Speed applied from "Downshift torque" to the motor stop.
Max. time
30 sec by default. The tool stops when the time is reached.
Motor control
Starting at the "Start" signal, the tool runs with a programmed acceleration up to "Rundown speed".
The tool keeps running at "Rundown speed".
Once "Downshift torque" has been reached, the speed changes to "Downshift speed".