This Manual is applicable to Soft LED2 XL Vari-White
Revised on June 2020
ILT ITALY srl
Via Cancelliera, 10/a
00041 Albano Laziale (Rome) Italy
tel. +39 06-902901 fax +39 06-90231051
www.desisti.it
INFORMATION PROVIDED ON THE DISPLAY
Display of Correlated Colour Temperature
Display of LED Case TEMPERATURE
Display of DMX Leve
DMX Address
Display of local potentiometer level (when in local control or turned off turned DMX controller)
LOCAL CORRELATED COLOUR
TEMPERATURE CONTROL
This Function is to LOCALLY ADJUST the CORRELATED
COLOUR TEMPERATURE from 2.800°K to 6.600°K
(Product is delivered with d efault setting of the CCT at
2.800°K).
The rotation of KNOB 1 will determine CCT increments
according to the following table (STEP MODE).
If a continuous CCT adjustment is required (LINEAR MODE)
it is necessary to operate through a DMX Console: please
see DMX parameters above.
local dimming setting will be maintained and will be automatically recalled
after power off, when turnig the power on again.
LOCAL OR REMOTE CONTROL SETTINGS
The LED Fresnel has the facility to block the LOCAL DIMMING and CCT SETTING and
maintain it when the Power is turned first OFF and then ON again. This allows for the Light
to be tuned and focused locally and its dimming plus CCT level can be blocked, so tghat for
instance a system lighting a Set can be operated by a remote switch or simple brackers by
turning POWER ON.
The machine is set to Auto save OFF as default: in this condition the Fixture can be
controlled locally until a DMX device is connected to it. Once the Console will be acting it
will take priority over any local control.
To turn the Autosave ON please follow these instructions:
- rotate KNOB 2 and select Auto save OFF
- press KNOB 2 to highlight the status of Auto save, in this case OFF
- rotate KNOB 2 to turn the status od Auto save to ON and press it
- leave the setting in this condition: the light will ignore any DMX control
In this code any local dimming setting will be maintained and will be automatically recalled
after power off, when turning the power on again