background image

Installation and Commissioning

Instructions

              Note: HP2000 required for commissioning

 

Ex-Or

Haydock Lane, Haydock, Merseyside WA11 9UJ

Tel: +44 (0)1942 719229 
Fax: +44 (0)1942 272767  
Email: [email protected]
www.ex-or.com

At the end of their useful life 
the packaging and product 
should be disposed of via a 
suitable recycling centre.
Do not dispose of with normal 
household waste.
Do not burn.

   MLS2500D / MLS2500DF

   MLS2500DWL* / MLS2500DWLF*

 MLS2500DALI / ML2500DALIF

   MLS2500DALIWL* / MLS2500DALIWLF*

Digital Mid Range LightSpot

*

with Wireless OneSwitch facility

  

 MLS2500D(WL)

MLS2500DALI(WL)

   

MLS2500D(WL)F

MLS2500DALI(WL)F

ii) Switching Photocell Only (Passive Photocell = YES)

Use Passive mode in applications where light level regulation is not required (e.g. when controlling non-dimmable 
ballasts), but it is desirable to hold off the controlled lighting when natural light is sufficient. The parameter Set-Point 
Low  on  the  HP2000  menu  is  designed  to  programme  the  MLS2500D's  passive  photocell  set  point,  which 
determines  whether  the  lights  will  be  allowed  to  turn  on  as  an  unoccupied  area  is  entered.  The  threshold  is 
programmed as a number between 1 (darkest) and 1023 (brightest). This number is not scaled to correlate with ‘lux’ 
measurements made using a light meter, but nevertheless is a true representation of the light level perceived by the 
MLS2500D. 

In order to assist with selection of the appropriate Set-Point Low  setting, the light level currently perceived by the 
detector (in terms of a number between 1 and 1023) can be viewed on the HP2000 screen briefly following a 
download operation. The number represents the light level immediately before the download took place. 

Tip: Turn 

the lights off first (using user-remote found in utilities) if you want to measure the perceived light level with no 
contribution from the controlled lighting.

 

Technical Data

 

MLS CABLE: 1.5mm sq unscreened twisted-pair (applicable when detector used as part of a full MLS Digital 
Managed Lighting System); see Application Note AN4001.
OPERATING VOLTAGE: 230V ~ 50Hz (UK & Europe).
SWITCH CAPACITY: 10 Amps max any lighting load except incandescent lamps: 1500W max (at 230V~).
MAX RECOMMENDED MOUNTING HEIGHT: 3.5m.
RANGE: Adjustable up to 20m.
OFF DELAY: 10 seconds to 96 hours.
WEIGHT:  160g. 
COLOUR: White.

     

MATERIAL: Flame retardant PC/ABS.

     

IP RATING:

43 when ceiling mounted, 4X when wall mounted.      

   
  

Contact Ex-Or Technical Helpline on 01942 719229 for guidance on installation and commissioning.

Important Additional Notes

 in order 

to  achieve  a  predicted  lamp  life.    Please  check  with  the  manufacturer  of  the  luminaires  to  ensure  that  they  are 
compatible with automatic controls in this respect. 

1.

All terminals on this product are provided for final connections.  It is not intended that the product be used as a junction 
box for looping cables. 

2.

Although nominally 12V, the dimming output is not ELV and therefore should be treated with the same respect as mains 
with regard to wiring practice.  

3.

Take care when choosing a location for this equipment since this type of device is capable of detecting large moving 
metal objects well beyond the normal range at which it is sensitive to human targets.

4.

Please note that, although configurable as a regulating photocell, [closed-loop dimming according to daylight], due to 
the probable corner-of-room location where there will be excessive influence by daylight reflected from the walls, this 
product is not intended to achieve precise light level regulation measured on the working plane.

5.   This  equipment  switches  lights  no  more  frequently  than  would  a  responsible  human  occupant.    However, 

manufacturers of some lighting types (e.g. ‘2D’ luminaires) may specify a maximum number of switching cycles 

W4364A

WMK 

  

Wall-mounting kit for MLS2500D

(Supplied assembled)

Vertical installation

Use this method of mounting for racking aisle 
applications and where adjustment in the 
vertical plane will give improved control over 
the precise point of entry detection.

Horizontal installation

For general applications where 
ceiling mounting is not 
convenient and wide angle 
coverage in the horizontal plane 
is desirable.  The WMK can be 
screwed to a hard surface or the 
lid of a conduit stop-end box.

Exploded view of MLS2500DF
   for fixing into ceiling tiles.