Desisti BOTTICELLI 3120 Скачать руководство пользователя страница 4

 

 

 

4.

 

INSTALLATION INSTRUCTIONS 

 
Before connecting the luminaire to the electrical mains ensure that: 

A - Earth line is present on the power socket. 
B - The mains voltage is within the rated range of the luminaire (see technical data on the 
rating label) 
C - The lamps fitted: 

!

 

are  among  the  recommended  lamps  (see  De  Sisti  Lighting  catalogue  or  contact 

your De Sisti dealer) 

!

 

have the same nominal voltage as the mains supply  

!

 

have  a  nominal  power  not  higher  than  1  fourth  of  the  maximum  power  of  the 

luminaire 

NB: the luminaire nominal frequency rate is 0 - 60 Hz. 

D - The front safety shields against the lamp explosion are present and in good condition. 

Depending on luminaire type these items may consist of: 

!

 

wire mesh guard 3 mm x 3 mm  

!

 

safety or dichroic glass plus wire guard 12 mm x 12 mm 

!

 

Fresnel lens plus wire guard 25 mm x 25 mm. 

Shields, lenses safety or dichroic glasses shall be changed if they have become visibly 

damaged to such an extent that their effectiveness is impaired, for example by cracks or deep 
scratches.  
 
5.

 

LAMP INSTALLATION AND REPLACEMENT 

 
The following procedure should be adopted: 
A - Ensure the luminaire is electrically isolated from the power supply. 
B - WAIT LEAST 5 MINUTES FROM SWITCHING OFF to avoid risk of injury from possible 
lamp explosion. Then open the front hinged door holding the lamp assembly. 
WARNING: AFTER THE ABOVE MENTIONED TIME THE LAMPS MAY STILL BE VERY HOT, 
USE PROPER THERMAL PROTECTION (EG. GLOVES). 
C - Check that the new lamps are of the correct type. 
D - Replace the lamps taking good note of the following: 

do not touch the bulb with bare-hands; oil and grease can contaminate the bulb surface 
and then reduce    the performance and the lamp life. The plastic cover which protects the 
lamp should not be removed until after fitting should the bulb become dirty due to hand 
contact or for any other reason, it can be cleaned with a cloth moistened with alcohol. 

E - Ensure that any safety device that has been removed is refitted correctly or that the lens 
door is securely closed. 
 

 
 
 
 
 

Содержание BOTTICELLI 3120

Страница 1: ...BOTTICELLI 5 000 W Quartz Halogen Softlight Standard EN 60598 2 17 Class 1 INSTRUCTION MANUAL MO D 3120 MAN UAL O P E R AT E D P O L E O P E R AT E D MO D 3122 ...

Страница 2: ...xperience in leading the innovation in the manufacturing of lighting products for the professional Entertainment Industry mean you can depend upon the quality of this product The BOTTICELLI 5 kW is a compact and robust softlight using 4 tungsten quartz halogen linear filament lamps having R7s sockets Length of 189 mm and max 1 25 kW power each 2 YOKE AND ACCESSORIES ASSEMBLY ...

Страница 3: ...Working conditions Insertion time 100 Working Position Max Tilting on vertical plane 90 from straight horizontal Ambient Temperature ta 20 C 45 C Humidity Not condensing Minimum distances from inflammable surfaces Top Back Sides Front 0 4 m 0 1 m 0 1 m 4 m The luminaire should never be OPERATED close to inflammable materials The ones indicated in the above table are the minimum distances recommend...

Страница 4: ...visibly damaged to such an extent that their effectiveness is impaired for example by cracks or deep scratches 5 LAMP INSTALLATION AND REPLACEMENT The following procedure should be adopted A Ensure the luminaire is electrically isolated from the power supply B WAIT LEAST 5 MINUTES FROM SWITCHING OFF to avoid risk of injury from possible lamp explosion Then open the front hinged door holding the la...

Страница 5: ...ass Class 1 it requires ground connection Protection Type IP 22 Max Housing Surface Temperature 220 C Weight of Fixture M O M O USA P O P O USA 15 5 kg 17 7 kg 16 5 kg 19 2 kg Weight of Egg crates 24 5 mm tickness 49 mm tickness 1 9 kg 3 4 kg Weight of color frame 0 85 kg USABLE LAMPS length watt filament 230 v 120 v ANSI LIF ANSI LIF 189 625 sc 8 P2 10 Not available 189 1000 sc 8 EKM P2 7 Not ava...

Страница 6: ...100 working hours In order to avoid explosion the lamp should be changed if it has become damaged or deformed Follow the instructions supplied by the lamp manufacturer C Check the condition of the safety shield see chapter 4 Installation Instructions point D before every use 8 SAFETY STANDARDS Europe This product conforms the Applicable European Directives and Standards as listed below America the...

Отзывы: