Desisti BOTTICELLI 3120 Скачать руководство пользователя страница 3

 

 

3.

 

SAFETY INSTRUCTIONS 

 

!

 

Professional  use:  This luminaire has been designed for professional use and must be 

operated by qualified personnel only. Not for residential use. 

!

 

Grounding: WARNING: THIS LUMINAIRE MUST BE GROUNDED 

!

 

Electrical  connections:  IMPORTANT  The  cores  in  this  mains  lead  are  colored  in 

accordance with the following code: 
 

 

Europe 

America 

Ground

 

Green & yellow 

Green  or  green  & 
yellow 

Neutral

 

Blue 

White 

Live

 

Brown 

Black 

 
In case the colors of the cores do not correspond to the colors of the connection points on 
your plug, please proceed as follows: 

 

the  green  or  green  and  yellow  core  must  be  connected  to  the  connection  point  marked 

with the letter E or with the symbol  

or colored in green or in green - yellow; 

 

the blue (or white) core must be connected to the connection point marked with the letter 

N or colored in black; 

 

the brown (or black) core must be connected to the connection point marked with the letter 

L or colored  in red. 

 

Working conditions 

 

!

 

Insertion time  

100% 

!

 

Working Position 

Max. Tilting on vertical plane 

±

90° from straight horizontal 

!

 

Ambient Temperature, t

a

 

-20° C 

÷

 +45° C 

!

 

Humidity 

Not condensing 

!

 

Minimum distances from 

inflammable surfaces 

Top 

Back 

Sides 

Front 

0,4 m. 

0,1 m. 

0,1 m. 

4 m. 

 

The  luminaire  should  never  be  OPERATED  close  to  inflammable  materials.  The  ones 
indicated in the above table are the minimum distances recommended. Other requirements 
for safe use are:  
A.

 

Do  not  cover  the  apertures  of  the  luminaire  housing.  They  are  essential  for  correct 

ventilation. Do not use on the floor. It reduces the ventilation. 

B.

 

Use only original accessories and spares from De Sisti Lighting. 

C.

 

Before hanging the luminaire ensure that the suspension point (or the stand) is properly 

rated to accept the luminaire weight. 

D.

 

In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. 

E.

 

A suitable secondary safety suspension device (safety cable, chain or equivalent) must be 

fitted between the suspension point and stirrup. 

F.

 

Don`t use the luminaire in an environment where the ambient temperature is higher than 

the maximum nominal one, t

a

, indicating the rating. 

Содержание BOTTICELLI 3120

Страница 1: ...BOTTICELLI 5 000 W Quartz Halogen Softlight Standard EN 60598 2 17 Class 1 INSTRUCTION MANUAL MO D 3120 MAN UAL O P E R AT E D P O L E O P E R AT E D MO D 3122 ...

Страница 2: ...xperience in leading the innovation in the manufacturing of lighting products for the professional Entertainment Industry mean you can depend upon the quality of this product The BOTTICELLI 5 kW is a compact and robust softlight using 4 tungsten quartz halogen linear filament lamps having R7s sockets Length of 189 mm and max 1 25 kW power each 2 YOKE AND ACCESSORIES ASSEMBLY ...

Страница 3: ...Working conditions Insertion time 100 Working Position Max Tilting on vertical plane 90 from straight horizontal Ambient Temperature ta 20 C 45 C Humidity Not condensing Minimum distances from inflammable surfaces Top Back Sides Front 0 4 m 0 1 m 0 1 m 4 m The luminaire should never be OPERATED close to inflammable materials The ones indicated in the above table are the minimum distances recommend...

Страница 4: ...visibly damaged to such an extent that their effectiveness is impaired for example by cracks or deep scratches 5 LAMP INSTALLATION AND REPLACEMENT The following procedure should be adopted A Ensure the luminaire is electrically isolated from the power supply B WAIT LEAST 5 MINUTES FROM SWITCHING OFF to avoid risk of injury from possible lamp explosion Then open the front hinged door holding the la...

Страница 5: ...ass Class 1 it requires ground connection Protection Type IP 22 Max Housing Surface Temperature 220 C Weight of Fixture M O M O USA P O P O USA 15 5 kg 17 7 kg 16 5 kg 19 2 kg Weight of Egg crates 24 5 mm tickness 49 mm tickness 1 9 kg 3 4 kg Weight of color frame 0 85 kg USABLE LAMPS length watt filament 230 v 120 v ANSI LIF ANSI LIF 189 625 sc 8 P2 10 Not available 189 1000 sc 8 EKM P2 7 Not ava...

Страница 6: ...100 working hours In order to avoid explosion the lamp should be changed if it has become damaged or deformed Follow the instructions supplied by the lamp manufacturer C Check the condition of the safety shield see chapter 4 Installation Instructions point D before every use 8 SAFETY STANDARDS Europe This product conforms the Applicable European Directives and Standards as listed below America the...