INSTRUCTIONS PERTAINING TO RISK OF FIRE OR INJURY TO 

PERSONS.  READ ALL INSTRUCTIONS.  IMPORTANT SAFETY 

INSTRUCTIONS.  SAVE THESE INSTRUCTIONS.

DANGER - RISK OF SHOCK - DISCONNECT POWER BEFORE 

INSTALLATION!  Please read all instructions before installation.  

• Keep these instructions for future reference.

• Must be installed by a qualified electrician in accordance with national and

local standards.  Designplan is not responsible for fixtures installed without

regard to these standards.

The main power connection must be in ac-cordance with local electrical

codes.

• Unauthorized alterations or tampering of product voids warranty.

• Suitable for 

OUT

DOOR applications.

IF

IP

65

120

V

AC

  Maintenance

Scheduled maintenance must be carried out once a year on all lighting devices, regardless of appliance 

class and type of use.  It must include the following operations:

• Periodically clean fixtures to remove dirt from gratings and screw heads.

• Check tightness of screws on various parts of the device.

• Check that all cable glands and cables are intact and tight. Check that the glass or plastic 

lens

 is

 

intact, and replace it if broken or damaged.

• The internal components such as the ballast, 

driver,

 washers and screws must not show clear

 

signs

 

of oxidation or rust. Clear traces of rust and oxidation will indicate the presence of water inside

 

the

 

device.

• In the case of damage, the components must be replaced by original components or spare parts.

Содержание IF

Страница 1: ...ance with local electrical codes Unauthorized alterations or tampering of product voids warranty Suitable for OUTDOOR applications IF IP65 120VAC Maintenance Scheduled maintenance must be carried out once a year on all lighting devices regardless of appliance class and type of use It must include the following operations Periodically clean fixtures to remove dirt from gratings and screw heads Chec...

Страница 2: ...esignplan Lighting Inc installation instructions sales designplan com www designplan com P 908 996 7710 F 908 996 7042 2 of 5 IF Fixture Installation ground 1 49 ø105 mm 4 13 ø 9 0 m m 3 5 4 ø29 5 mm 1 16 4 29 ø 7 5 mm 0 29 2 95 1 57 6 7 19 68 27 56 35 43 ...

Страница 3: ... the hole in the base plate 9 7 8 of cable length is suffi cient Align the base horizontally and fix it whith the included screws Connect the power cable to the incluced TH387 connector 1 Neutral 2 Phase 4 Ground Only Procection class I Plug the connected connector to the one already present in the luminaire Insert the bollard onto the base align it and fix it with the included headless screws 1 4...

Страница 4: ...yright 2019 Designplan Lighting Inc installation instructions sales designplan com www designplan com P 908 996 7710 F 908 996 7042 4 of 5 IF Fixture Installation Wall A 4 56 6 2 94 A 2 1 2 53 1 48 0 19 0 12 0 19 0 19 2 36 1 49 1 06 0 47 0 53 ...

Страница 5: ...f the luminaire Drill two holes in the wall with a horizontal distance of 60 mm 2 36 Push the power cable through the rubber bushing Mount the base part on the wall using the included screws Connect the power cables to the clamps brown Phase blue Neutral green yellow ground If Safety class II use the silicon tubes on phase and neutral cable Re mount the head of the luminaire on the base part and f...

Отзывы: