background image

11. Turn the bottom temperature control 

knob clockwise for hotter water and 
anti-clockwise for cooler water. Allow a 
few seconds between selections - for 
the temperature change to reach the 
showerhead.

NOTE: When the temperature is changed 
the flow rate alters.

12. Push the 

STOP/START

 button to stop the 

flow.

13. Switch of pull-cord or wall mounted switch. 

COMMISSIONING THE SHOWER / OPERATING INSTRUCTIONS

SECTION 10

Operating the shower

1.  Switch on pull-cord or wall mounted switch. 

The 

‘Power’

 neon will illuminate indicating 

the switch is on.

2.   Press the 

STOP/START

 button for 

immediate water flow.

3.   Select your power setting using the top 

control. The shower has three positions 

‘Cold’

‘Low’

 power and 

‘High’

 power.

‘Cold’

 setting 

(Solid Blue Symbol)

Adjustment of the flow control on this 
setting will only alter the flow of water not 
the water temperature.

‘Low’

 setting 

(Outline Red Symbol)

:

This is the low power setting for 
economy during warmer months 
or when a cool shower is required.
Temperature adjustment is via the 
bottom temperature control.

‘High’

 setting 

(Solid Red Symbol)

:

This is the full power setting. 
Temperature adjustment is via the 
bottom temperature control.

8

SECTION 9

Commissioning the shower

1.  Make sure that the electrical supply has 

been isolated at the double pole isolating 
switch.

2.  Turn the top power selector knob to the 

‘Cold’

 setting 

(Solid Blue Symbol)

.

3.  Turn the bottom temperature control knob 

anti-clockwise to the full cold position.

4.  Ensuring the water supply is fully on at the 

mains stop cock and isolating service valve 

(if fitted)

, check that water is not leaking 

from the bottom of the case.

5.  Switch on the electrical supply at the 

double pole switch. The 

‘Power’

 neon 

indicator will light.

6.  Press the

 STOP/START

 button. Check 

that water flows freely from the shower 
within a few seconds. The water from the 
showerhead will be at full force and at a 
cool temperature.

7.  Rotate the bottom temperature control 

knob slowly clockwise fully. This will 
gradually reduce the flow with the water 
temperature remaining cool.

8.  Return the knob anti-clockwise to 

maximum flow.

9.  Now turn the top power selector knob to 

the 

‘Low’

 setting 

(Outline Red Symbol)

.

Allow a few seconds for the warmer 
temperature to reach the showerhead 
- this shows that the 

‘Low’

 power setting 

is operating correctly.

10. Now turn the top power selector knob 

to the 

‘High’

 setting 

(Solid Red Symbol)

The temperature at the showerhead will 
rise further - this shows that the full power 
setting is operating correctly.

IMPORTANT

 

To comply with National Water Council bylaws 
a double check valve must be fitted with all 
flexible shower accessories where it is possible 
that the shower head may come into contact 
with used water i.e. in the bath or shower tray.

SECTION 5

Plumbing connection

Plumbing the shower unit must precede 
wiring.

 

Turn off the water supply at the isolating stop 
tap.

Having determined the direction of the inlet 
water supply: 

Top

 (falling), 

Bottom

 (rising), 

or 

Back

 inlet. It is necessary to remove the 

appropriate plastic cross section from the back 
plate, before commencing with the installation 
(See diagrams 

Fig 1 & Fig 2

).

PLUMBING CONNECTION 

5

The back plate is fitted with removable inserts 
for 

Top

 (falling) and 

Bottom

 (rising) inlet mains 

water pipework to the shower unit.

We have incorporated into the bottom right-
hand side of the back plate an easy removable 
trim section, to allow easy access when 
connecting the water supply. 
(

Please Note! 

Remember to replace this trim 

section before refitting the cover).

Remove this plastic 

cross-section when using 

the ‘REAR’ or ‘TOP’ entry 

point for plumming

Remove this plastic 

cross-section when using 

the ‘BOTTOM’ entry point 

for plumming

Connect the mains water supply to the inlet 
of the shower unit using a 15mm copper or 
stainless pipe with a 15mm compression 
elbow or 15mmm push-fit elbow. 

Do not 

use excessive force when making the 
connection to the unit

.

IMPORTANT

 

Before turning on the water supply to the 
shower unit the water supply pipe should be 
flushed out to remove debris. This can be 
achieved by connecting the flexible hose to the 
15mm compression elbow and turning on the 
mains water supply long enough to clear the 
debris.

After flushing the pipework ensure that the 
shower unit is positioned squarely on the wall 
and tighten the screws. Tighten all plumbing 
connections and check the pipework for leaks.

Fig 1

Fig 2

ds3000 12pg booklet_2009_pag.ind10-11   10-11

30/9/09   9:45:11 am

Содержание ds3000

Страница 1: ... does not affect your statutory rights GUARANTEE Before telephoning the Designa Customer Service Department you should ensure that you have the model number power rating serial number and date of purchase The Designa Customer Service Department will be able to inform you whether the fault can be rectified by the provision of a replacement part or an on site visit by a Qualified Service Engineer If...

Страница 2: ...ct Low power Water too cool or cold Water flow too high Reduce flow rate via temperature control Water pressure below minimum required See rating label Reduction in ambient water temperature Select High power Water flow is poor Shower head is blocked Clean the showerhead Ensure showerhead is as specified by manufacturer The temperature control knob is set at its hottest setting Increase the power ...

Страница 3: ... how your Designa shower unit operates The flow rate of water passing through the shower unit determines the water temperature The lower the flow the warmer the water the higher the flow the cooler the water The temperature produced by the shower unit will vary between seasons on any one setting of the temperature control This is due to variance in the temperature of the water supply which becomes...

Страница 4: ...plete with the control knobs Place the shower unit on the wall and mark the location of the fixing screws through the back plate Carefully drill the holes as marked using a sharp 5 5mm masonry drill Fix the shower unit to the wall using the plugs and screws provided do not fully tighten at this stage This appliance is not intended for use by persons Including children with reduced physical sensory...

Страница 5: ...lector knob to the Low setting Outline Red Symbol Allow a few seconds for the warmer temperature to reach the showerhead this shows that the Low power setting is operating correctly 10 Now turn the top power selector knob to the High setting Solid Red Symbol The temperature at the showerhead will rise further this shows that the full power setting is operating correctly IMPORTANT To comply with Na...

Страница 6: ...pped under screws Ensure the cable clamp is used to secure the cable SECTION 7 Fitting the cover into position NOTE It is necessary to align the D flat on the reverse side of the Power Selector and Temperature knobs with their opposite control spindles before the cover is located Secure the cover with the two fixing screws provided IMPORTANT Turn the flow control knob anti clockwise until the valv...