background image

DIMENSIONS

2

690 mm

218 mm

339 mm

TROUBLESHOOTING GUIDE

11

SYMPTOM

POSSIBLE CAUSE

ACTION

No hot water.

Power setting is at Cold.

Select a heat setting.

Low Water Pressure.

The water supply has dropped below the minimum 
operating pressure. Switch off other cold water 
devices and retry.

The thermal cut-out has operated.

Turn the Power knob to cold. Switch off the 
shower. Clean the shower head, and restart the 
shower. Select a heat setting. If no hot water is 
produced call the Designa Service Centre.

Power indicator  
is not lit.

The power setting is on cold.

Turn the power setting to a heat setting and the 
indicator should light.

Water pressure below minimum 
required.

Check If water mains stop valve is fully open.

Water too hot.

Not enough water flowing through the 
shower.

Increase the flow rate via temperature control.

Blockage in supply.

Blocked spray head - clean or replace blocked 
spray plate in spray head.
Check If stop valves are fully open. Check for 
blockage in inlet filter.

Increase in ambient water temperature.

Re-adjust flow rate to give increased flow.
Select ‘Low’ power.

Water too cool  
or cold.

Water flow too high.

Reduce flow rate via temperature control.

Water pressure below minimum 
required (See rating label).
Reduction in ambient water 
temperature.

Select ‘High’ power.

Water flow is poor.

Shower head is blocked.

Clean the showerhead. Ensure showerhead is as 
specified by manufacturer.

The temperature control knob is set at 
its hottest setting.

Increase the power setting by turning the power 
knob to hot and increase the flow using the 
temperature control knob.

Water continues 
to drip from the 
handset when 
switched off.

Water is draining from the shower unit, 
after use.

This is normal, no action required. Should water 
continue to drip after a few minutes contact’ 
Designa Service Centre.

Pressure relief 
device has 
operated (water 
ejecting from 
Pressure Relief 
tube).

Blocked spray head.

Remove handset and run water through the 
shower and hose to remove any dirt that may be 
trapped In the system. Clean or, if possible, replace 
the spray plate in the spray head and then fit a new 
Pressure Relief Device.

Twisted/blocked flexible shower hose.

Check the hose is not restricted anywhere along its 
length. Replace the hose if necessary and fit a new 
Pressure Relief Device.

ds3000 12pg booklet_2009_pag.ind4-5   4-5

30/9/09   9:45:06 am

Содержание ds3000

Страница 1: ... does not affect your statutory rights GUARANTEE Before telephoning the Designa Customer Service Department you should ensure that you have the model number power rating serial number and date of purchase The Designa Customer Service Department will be able to inform you whether the fault can be rectified by the provision of a replacement part or an on site visit by a Qualified Service Engineer If...

Страница 2: ...ct Low power Water too cool or cold Water flow too high Reduce flow rate via temperature control Water pressure below minimum required See rating label Reduction in ambient water temperature Select High power Water flow is poor Shower head is blocked Clean the showerhead Ensure showerhead is as specified by manufacturer The temperature control knob is set at its hottest setting Increase the power ...

Страница 3: ... how your Designa shower unit operates The flow rate of water passing through the shower unit determines the water temperature The lower the flow the warmer the water the higher the flow the cooler the water The temperature produced by the shower unit will vary between seasons on any one setting of the temperature control This is due to variance in the temperature of the water supply which becomes...

Страница 4: ...plete with the control knobs Place the shower unit on the wall and mark the location of the fixing screws through the back plate Carefully drill the holes as marked using a sharp 5 5mm masonry drill Fix the shower unit to the wall using the plugs and screws provided do not fully tighten at this stage This appliance is not intended for use by persons Including children with reduced physical sensory...

Страница 5: ...lector knob to the Low setting Outline Red Symbol Allow a few seconds for the warmer temperature to reach the showerhead this shows that the Low power setting is operating correctly 10 Now turn the top power selector knob to the High setting Solid Red Symbol The temperature at the showerhead will rise further this shows that the full power setting is operating correctly IMPORTANT To comply with Na...

Страница 6: ...pped under screws Ensure the cable clamp is used to secure the cable SECTION 7 Fitting the cover into position NOTE It is necessary to align the D flat on the reverse side of the Power Selector and Temperature knobs with their opposite control spindles before the cover is located Secure the cover with the two fixing screws provided IMPORTANT Turn the flow control knob anti clockwise until the valv...

Отзывы: