FOR YOUR SAFETY 

READ BEFORE LIGHTING

 WARNING: Keep flue open 

when operating unit.

 WARNING: If you do not fol-

low  these  instructions  exactly, 

a  fire  or  explosion  may  result 

causing property damage, per-

sonal injury or loss of life.

A.  This appliance has a pilot which must be 

lighted with a piezo ignitor. When lightning 

the pilot, follow these instructions exactly.

B.  BEFORE LIGHTING smell all around the 

appliance area for gas. Be sure to smell next 

to the floor because some gas is heavier than 

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not 

use any phone in your building.

• Immediately call your gas supplier from 

a  neighborʼs  phone.  Follow  the  gas 

supplierʼs instructions.

• If you cannot reach your gas supplier, call 

the fire department.

C.  Use only your hand to push in or turn gas 

control knob. Never use tools. If the knob 

will not push in or turn by hand, do not try 

to repair it, call a qualified technician. Force 

or attempted repair may result in a fire.

D.  Do not use this appliance if any part has 

been  under  water.  Immediately  call  a 

qualified service technician to inspect the 

appliance and to replace any part of the 

control system and any gas control which 

has been under water.

OPERATING HEATER

Continued 

LIGHTING 

 INSTRUCTIONS

NOTICE: During initial operation 

the  appliance  will  emit  a  slight 

odor for an hour or two. This is 

due to the "burn-in" of the inter-

nal  paints  and  lubricants  used 

in  manufacturing.  For  the  first 

few hours, operate the appliance 

with doors and windows open to 

encourage dissipation of odor.

1.  STOP! Read the safety information, col-

umn 1. 

2.  Make sure equipment shutoff valve is fully 

open.

3.  Set switch in the Local position.

4.  Wait five (5) minutes to clear out any gas. If 

you then smell gas STOP! Follow the safety 

information above. If you don't smell gas, 

go on to the next step.

5.  Turn PilotStat knob to PILOT. Push in on 

PilotStat knob and press Piezo button 

 

until the pilot is lit.

6.  Continue to hold PilotStat knob in until 

LED  blinks  (one  brief  blink  every  two 

seconds)  then  release  knob. 

Note: 

You 

will need to hold the knob in for about one 

minute.

7.  Turn PilotStat knob to ON See Figure 12, 

page 9.

  WARNING:  Moving  the  Lo-

cal/Remote  switch  can  cause 

the  main  burner  to  come  on 

immediately.  Stand  away  from 

the  main  burner  when  moving 

the local/remote switch to avoid 

possible injury.

USING TRANSMITTER/ 

REMOTE

1.  Move  switch  to  REMOTE  position  (see 

Figure 12, page 9).

2.  Press FAN

 or FLAME

 key within 

30 seconds.

3.  Make sure LED turns on for one second.

Содержание HCA-18-RFN

Страница 1: ...any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier VENTED DECORATIVE GAS LOG HEATER OWNER S OPERATION AND IN...

Страница 2: ...es ANSI Z233 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indi cated on the rating plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resal...

Страница 3: ...ts Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this log set WARNING Any change to this log set or its controls can be dangerous WARNING Donotuseablow erinsert heatexchangerinsertor otheraccessorynotapprovedfor use with this appliance WARNING This appliance is equipped for natural or pro pane LP gas Field conversi...

Страница 4: ...en the vents before operating heater 7 Toreducethecreationofsoot followtheinstruc tions in Cleaning and Maintenance page 12 8 Do not run heater where flammable liquids or vapors are used or stored under dusty conditions 9 Do not burn solid fuel in the fireplace after installing the log set Do not use this log set to cook food or burn paper or other objects SAFETY INFORMATION Continued 10 Log set bec...

Страница 5: ...highly heated A dirtychimneyfluemaycreateand distribute soot within the house Inspectchimneyfluefordamage If damaged repair flue damper before operating appliance CAUTION Thisheatercreates warmaircurrents Thesecurrents move heat to wall surfaces next to heater Installing heater next tovinylorclothwallcoveringsor operatingheaterwhereimpurities such as but not limited to to bacco smoke aromatic candles...

Страница 6: ...ed pro pane LP tank may cause an explosion Propane LP Supply Tank External Regulator Vent Pointing Down Figure 3 External Regulator with Vent Pointing Down Figure 2 Attaching Damper Clamp Manufactured Fireplace Masonry Fireplace Damper Damper Clamp Damper Damper Clamp Damper VENTING SPECIFICATIONS FOR INSTALLATION The fireplace chimney flue and vent must be draft ing properly To check the vent for p...

Страница 7: ...y to freeze A sediment trap traps moisture and contaminants This keeps them from going into heater controls If sediment trap is not installed or is installed wrong heater may not run properly Figure 4 Gas Connection PurchasetheoptionalCSAdesign certifiedshutoff valve from your dealer See Accessories page 18 Minimum inlet pressure for purpose of input adjustment Approved Flexible Gas Hose If allowed...

Страница 8: ...e leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once Gas Pressure Check The appliance regulator controls the burner pres sure which should be checked at the pressure test point 1 8 NPT plugged tap located near the on the control valve identified OUT for the manifold side and IN for inlet pressure Make sure operating pressures are within the limits shown in Sp...

Страница 9: ...led OPERATING APPLIANCE The RF Millivolt valve control used on these appli ances allows you to turn the gas log set on or off use a timer to automatically operate the log set increase or decrease flame height fan speed or timing An easy to read display gives you information about room temperature set temperature flame height level fan speed level and a countdown timer as well as a low battery indica...

Страница 10: ...he appliance and to replace any part of the control system and any gas control which has been under water OPERATING HEATER Continued LIGHTING INSTRUCTIONS NOTICE During initial operation the appliance will emit a slight odor for an hour or two This is due to the burn in of the inter nal paints and lubricants used in manufacturing For the first fewhours operatetheappliance with doors and windows ope...

Страница 11: ...ntil mode is OFF Pilot stays lit Shut Off Main Burner Without Remote Turn PilotStat knob to PILOT Pilot stays lit Shut Off Main Burner and Pilot Turn PilotStat knob to OFF CAUTION During normal shutdown of this unit a flash may be observed due to the na ture of the burner components Remain clear of the unit during the shutdown process INSPECTING BURNERS Check pilot flame pattern and burner flame pat ...

Страница 12: ...e slide the battery compartment door off to expose old batteries Place new batteries into housing and reattach door See Figure 15 Figure 15 Bottom of Transmitter Showing Battery Compartment and Door TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESAʼs Technical Service Department at 1 866 672 6040 When calling please have your model ...

Страница 13: ...ntrol system be sure external gas shut off valve located at gas supply inlet is in the ON position POSSIBLE CAUSE REMEDY OBSERVED PROBLEM 1 Defective ignitor no spark at electrode 2 Defective or misaligned electrode at pilot spark at electrode 3 Gas supply pressure errant 4 Pilot orifice plugged 1 Defective pilot generator thermocouple Spark ignitor will not light pilot after repeated triggering of...

Страница 14: ...2 Check thermopile with mil livolt meter Take reading at thermopile terminals of gas valve It should read 325 mil livolts minimum with optional wall switch OFF Replace faulty thermopile if reading is below specified minimum 3 Check burner orifice for stop page and remove 1 Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple see Figure 13 page 11 POSSIBLE CAUSE 1 Wall switch ...

Страница 15: ... 10 6 3 W C 3 5 1 6 W C 10 6 3 W C Inlet Gas Pressure in of water Maximum 10 5 W C 13 W C 10 5 W C 13 W C Minimum 5 0 W C 11 W C 5 0 W C 11 W C Valve Operation RF Millivolt RF Millivolt RF Millivolt RF Millivolt Orifice Size 21 42 28 45 For purpose of input adjustment WIRING DIAGRAM Outlet Pressure Tap Inlet Pressure Tap Piezo Gas Control Knob Pilot Adjustment Screw Pilot Burner Assembly Pilot Tube...

Страница 16: ...om 115481 01B 16 ILLUSTRATED PARTS BREAKDOWN HCA 24 RFN HCA 24 RFP HCA 18 RFN HCA 18 RFP HCM 24 RFN HCM 24 RFP HCM 18 RFN HCM 18 RFP HKE 24 RFN HKE 24 RFP HKE 18 RFN HKE 18 RFP 1 3 7 6 5 4 2 8 9 10 12 13 17 15 16 11 ...

Страница 17: ... 115492 01 115492 01 115493 01 Air Shutter 1 10 115454 01 115454 01 115454 01 115454 02 Venturi 1 11 115452 01 115452 01 115452 01 115452 01 Valve Bracket 1 12 115488 01 115488 01 115488 01 115488 01 Tube 1 13 14396 14396 14396 14396 Adapter Valve 1 14 115489 01 115489 01 115489 01 115489 01 Adapter Orifice 1 15 115450 01 115450 01 115451 01 115451 01 Burner Plate 1 16 115456 01 115456 01 115456 01...

Страница 18: ... on the back page of this manual EQUIPMENT SHUTOFF VALVE GA5010 Equipment shutoff valve with 1 8 NPT tap Fits 1 2 pipe FIREPLACE HOOD Black GA6050 Brass GA6052 Antique Brss GA6053 Helps deflect heat away from mantel or wall ab ove fireplace Fits opening 28 to 4 wide DAMPER CLAMP GA6080 Not Shown Permanently opens chimney flue damper for vented operation LAVA ROCK GA6060 Not Shown Order when addition...

Страница 19: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________...

Страница 20: ...nostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TOTHE FULLEXTENTALLOWED BYTHE LAWOFTHE JURISDICTIONTHATGOVERNSTHE SALE OF THE PRODUCT THIS EXPRESSWARRANTYEXCLUDESANYANDALLOTHER EXPRESSEDWARRAN TIESANDLIMITSTHEDURATIONOFANYANDALLIMPLIEDWARRANTIES INCLUDINGWARRANTIES OF MERCHANTABILITY AND FITNESS FOR A...

Отзывы: