PERFORMING A WRIST STRAP TEST

1.  Use the wrist strap test jack to ground the operator’s 

 

wrist strap.

2.  While wearing the wrist strap, touch the tester’s test 

 

plate to determine if the operator’s wrist strap will 

 

act as a path-to-ground and ensure the presence of a 

 

current-limiting resistor in the wrist strap.

A “PASS” test result is indicated by illumination of the green 

TEST LED.  A “FAIL” test result is indicated if the LED does 

not illuminate.
If your ESD test fails, check your wrist strap to ensure it is 

being worn correctly and/or needs to be replaced.
NOTE: Failures may be caused by dry skin or minimal sweat 

layer.  For wrist straps, try using an approved dissipative 

hand lotion such as 

Menda Reztore™ ESD Hand Lotion

 to 

your wrist prior to use.
The AC Outlet Analyzer and Wrist Strap Tester may also be 

used to test smocks or garments that feature a grounding 

mechanism for operators using a coil cord connection.

Calibration

TESTING THE WRIST STRAP TESTER
A. LOW FAIL -

   Connect a 675 kilohm resistor @ 5%

 

 

tolerance between the Wrist Strap Test

 

 

Jack and the Test Plate.  The Wrist Strap

 

 

Test LED will momentarily illuminate then

 

 

turn off.  This test confirms the LOW FAIL

 

 

point.

B. LOW PASS -

  Connect a 825 kilohm resistor @ 5%

 

 

tolerance between the Wrist Strap Test

 

 

Jack and the Test Plate.  The Wrist Strap

 

 

Test LED will remain illuminated until the

 

 

resistor is removed from the Test Plate.

 

 

This test confirms the LOW PASS point.

C. HIGH PASS -

 Connect a 32 megohm resistor @ 5%

 

 

tolerance between the Wrist Strap Test

 

 

Jack and the Test Plate.  The Wrist Strap

 

 

Test LED will remain illuminated unitl the

 

 

resistor is removed from the Test Plate.

 

 

This test confirms the HIGH PASS point.

D. HIGH FAIL -

  Connect a 40 megohm resistor @ 5%

 

 

tolerance between the Wrist Strap Test

 

 

Jack and the Test Plate.  The Wrist Strap

 

 

Test LED should not illuminate.  This test

 

 

confirms the HIGH FAIL point.

Neutral

Load / Hot

Ground

Outlet LEDs
Wrist Strap

Test LED

Test Plate
Wrist Strap

Test Jack

Figure 3.  

98132

 features and components

Ground

Load / Hot

Neutral

Outlet LEDs
Wrist Strap

Test LED

Test Plate

Wrist Strap

Test Jack

Figure 4.  

98131

 features and components

Installation

PERFORMING AN AC OUTLET TEST

Plug the AC Outlet Analyzer into a proper electrical outlet.  

The unit will indicate the condition of the electrical outlet via 

the Outlet LEDs.

 

•  The green LED will illuminate if the outlet’s wiring 

is correct and the path to equipment ground via the 

equipment grounding conductor is intact.

 

•  The red LED will illuminate and the alarm will sound 

if the outlet’s wiring is incorrect and/or the path to 

equipment ground via the equipment grounding 

conductor is not intact.