TROUBLESHOOTING CHART

Limited Warranty

Desco expressly warrants that for a period of five (5) years from the date of purchase Desco CE Ionizers will be free of defects in material (parts) and
workmanship (labor).  Within the warranty period, a credit for purchase of replacement Desco CE Ionizers, or, at Desco's option, the CE Ionizer will be repaired
or replaced free of charge.  If product credit is issued, the amount will be calculated by multiplying the unused portion of the expected five year life times the
original unit purchase price. Call Customer Service at 909-627-8178 (Chino, CA) or 781-821-8370 (Canton, MA) for Return Material Authorization (RMA) and
proper shipping instructions and address.  Any unit under warranty should be shipped prepaid to the Desco factory.  Include a copy of your original packing slip,
invoice, or other proof of date of purchase. Warranty replacements will take approximately two weeks.

If your unit is out of warranty, Desco will quote repair charges necessary to bring your unit up to factory standards. Ship your unit freight prepaid and call
Customer Service at 909-627-8178 (Chino, CA) or 781-821-8370 (Canton, MA) for proper shipping instructions and address.

Warranty Exclusions

THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING
MERCHANTABILITY AND FITNESS FOR A PARTICULAR  PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED. The express warranty will not apply to
defects or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly maintain, clean or repair products.

Limit of Liability

Electronic ionizers use high voltage corona discharge and should not be used in or near flammable or explosive environments. In no event will Desco or any
seller be responsible or liable for any injury, loss or damage, direct or consequential, arising out of the use of or the inability to use the product.  Before using,
users shall determine the suitability of the product for their intended use, and users assume all risk and liability whatsoever in connection therewith.

Turn key to "SET" or "LOCK" 
position.

One or more emitter cassettes are

Push in emitter cassette(s) 

not fully inserted.

completely.

No Power

Check power cord or fuse.

Key is in "Lock " Position
(Blue indicator On).

Button depressed too quickly, 
or pressed too lightly.

"PWR" light is 

Emitter pins are dirty or 

Remove emitter cassette 

flashing red.

contaminated.

and clean emitters.

"PWR" light is  
flashing after emitter 

Refer to page 6 and 7 for

cassettes have been 

calibration instructions.

cleaned.

There is no audible 
alarm when "PWR" 
light is flashing red.

PROBLEM

POSSIBLE CAUSE

SOLUTION

Unit won't turn on

Fan speed or 
Balance won't
adjust

Unit is out of calibration.

Alarm switch is set to off.

Refer to page 5 and 6 
for switch location.

TB-2087

Page 8 of 8

© 2002 DESCO INDUSTRIES INC.

Employee Owned

Key is on "OFF" position.

Turn key to "Set" Position.

Push and hold buttons firmly.

DESCO WEST

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

- 90 Hudson Road, Canton, MA 02021 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com

                               9 / 9

                               9 / 9

Содержание 60478

Страница 1: ... System Limited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Lifecycle Information Desco Desco 60480 60480 For any questions you can email us directly For any questions you can email us directly sales integrated circuit com sales integrated circui...

Страница 2: ...rated circuit com Website www integrated circuit com CRITICAL ENVIRONMENT C E SERIES OVERHEAD IONIZER OWNER S MANUAL DESCO WEST 3651 Walnut Avenue Chino CA 91710 909 627 8178 Fax 909 627 7449 DESCO EAST 90 Hudson Road Canton MA 02021 781 821 8370 Fax 781 575 0172 Web Site http www desco com TB 2087 3 02 Page 1 of 8 Made in America ...

Страница 3: ...nization or other charge mitigating techniques shall be used at the workstation to neutralize electrostatic fields on all process essential insulators if the electrostatic field is considered a threat Ionization is used to neutralize charges on process necessary insulators and isolated semiconductors Some examples of process necessary insulators are the PC board itself plastic test stands plastic ...

Страница 4: ...d be supported as well to provide protection against any hazard to the operator S hooks are provided with each unit to facilitate mounting using the chain suspension method The ideal mounting height is 24 above the work surface although the ionizer may be located slightly higher or lower if required For maximum performance care should be taken to insure that the intake grills for the fans are not ...

Страница 5: ...wer may be opened when the cordset is removed In addition an IEC Outlet on the opposite end of the ionizer can supply power for a charged plate analyzer or for daisy chaining a second unit TB 2087 Page 4 of 8 Front Panel Display and Controls See figure 3 System Status is the information center on the front of the ionizer From it the operator can easily check the operational status of the ionizer P...

Страница 6: ...y switch can be set to the LOCK position and normal workstation use resumed If the ionizer is used in a manner not specified by the manufacturer the protection provided by the ionizer may be impaired Maintenance As with all ionizers periodic maintenance will be needed to provide optimum performance Reference IEC 61340 5 2 1paragraph 5 2 9 The frequency of monitoring ionizers really depends on how ...

Страница 7: ...s will often choose a much shorter interval especially if the product being worked on is very sensitive On very sensitive product we recommend checking the calibration any time an emitter cassette is removed and replaced Warning Do not attempt to calibrate this unit without proper equipment such as a charged plate analyzer Adjustments to the calibration controls should be performed by authorized t...

Страница 8: ...old the BAL switch to find its most positive point use the BAL switch to find its most negative point calculate the midpoint and set the balance using the BAL buttons to that point Example if the most positive point is 40V and its most negative point is 10V you would set the balance to 15V TB 2087 Page 7 of 8 5 Adjust each fan s output by placing the charge analyzer plate underneath it and turning...

Страница 9: ...LY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products Limit of Liability Electronic ionizers use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will Desco or any seller be responsible or liable for any ...

Отзывы: