A. Multi-Mount Monitor Jack:
Connects to the
Multi-Mount Monitor.
B. Operator LEDs:
Illuminates green when the
operator is properly grounded. Illuminates solid red and
audible alarm sounds when the operator is not properly
grounded.
C. Mat LEDs:
Illuminates green when the worksurface
is properly grounded. Illuminates red and audible alarm
sounds when the worksurface is not properly grounded.
Remote Alarm
Figure 6. Remote Alarm features and components
B
C
A
Installation
1. Remove the Multi-Mount Monitor from the carton,
and inspect for damage.
2. Locate an appropriate AC outlet near the
Multi-Mount Monitor, and test it for proper wiring
and grounding prior to use. The Desco AC Outlet
Analyzer or similar test equipment may be used to
verify the outlet’s functionality. Use item number
98132
for 120VAC North American outlets and item
number
98131
for 220VAC UK outlets.
3. Determine the mounting location of the Multi-Mount
Monitor. Its LEDs should be visible to the operator.
Secure the Multi-Mount Monitor to a surface using
its mounting tabs and the included pan-head screws
or dual lock fasteners.
4. Secure the ring termination of the white mat monitor
cord to the mat monitor screw terminal on the side
of the Multi-Mount Monitor. Ensure that the mat
monitor switch is enabled if using this monitored
circuit.
Remote Alarm
& cable are
purchased
separately
Multi-Mount
Monitor
Mat Monitor Cord
Push & Clinch Snap
Power Adapter
Grounded
Worksurface Mat
Figure 7. Installing the Multi-Mount Monitor and Remote
Alarm accessory
Use the flat head screw and
countersunk washer to keep
the cord from disconnecting
from the worksurface mat