background image

TB-3033

 Page 4 of 5

© 2011 DESCO INDUSTRIES INC.

Employee Owned

Figure 9: Using the Chargebuster Ion Gun

Pressures of 30-40 psi (0.2-0.28 MPa) are commonly 

used for decontaminating surfaces.  OSHA regulations 

recommend limiting hand-held air blow-off devices to 

maximum pressures of 30 psi (0.2 MPa).  The hose is rated 

at 65 psi (0.45 MPa) at temperatures up to 75°F (24°C), and 

the rating decreases at higher temperatures.  When using 

high pressures, consider the ambient room temperature as 

well as heat from surrounding equipment.
I.  Ensure that you are not holding down the trigger, and

 

turn on the power switch located at the top of the

 

console.  The power LED should illuminate.

II.  Hold the gun approximately six inches from the surface

 

you want to neutralize and blow-off.  Aim the nozzle

 

and hold down the trigger.  The LED on the back of the

 

gun should illuminate.  Typically, static charges are

 

discharged within one second.

III.  Release the trigger when the surface is clean.
If the optional foot switch is installed, you may use either 

the foot switch or gun trigger.

II.  Using a cloth moistened with the IPA solution, wipe

 

the exterior surfaces of the console and gun to

 

remove any dirt or dust that may have collected.

III.  Using a swab moistened with the IPA solution,

 

gently clean the emitter points on the gun.

 

Extremely dirty points increase the time needed to

 

discharge static and can affect the ionization

 

balance.

REPLACING THE DISPOSABLE FILTER

Desco recommends that the disposable filter be 

changed every 3 months or when it begins to look 

dirty.
I.  Turn power off at the console and disconnect the

 

console from the gas supply.

II.  Hold down the disposable filter release button on

 

the side of the console.

III.  Remove the hose and disposable filter from the

 

console by pulling the textured rubber plug where

 

the hose emerges from the console.  Rocking the

 

plug back and forth can help loosen the filter.  Do

 

not pull the hose itself.

IV.  Remove the disposable filter from the hose fitting by

 

depressing the metal release tab on the fitting and

 

pulling off the air filter.

V.  Replace with the new disposable filter by following

 

the procedure in the ASSEMBLY section on page

 

2.

Specifications

Ozone

 

< 0.005 ppm

 

(24 hour accumulation)

Hose

 

65 psi (0.45 MPa)

Power Output

 

120 VAC

Gas Input

 

20-65 psi (0.14 - 0.45 MPa)

 

Clean dry air or nitrogen

Disposable Filter

 

99.9% efficient

 

0.01 micron particles

 

0.008 micron coalescing

Hose Length

 

7' (2.13 m)

Console Dimensions

 

8.5" x 3.0" x 1.6"

 

(21.6 cm x 7.6 cm x 4.1 cm)

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: 

Desco.com

Maintenance

“All ionization devices will require periodic maintenance for 

proper operation. Maintenance intervals for ionizers vary 

widely depending on the type of ionization equipment and 

use environment. Critical clean room uses will generally 

require more frequent attention. It is important to set-up 

a routine schedule for ionizer service. Routine service is 

typically required to meet quality audit requirements.”  (ESD 

Handbook TR 20.20 section 5.3.6.7 Maintenance / Cleaning)

CLEANING THE COMPONENTS

I.  Turn off the console and disconnect it from its

 

electircal power and gas supply sources.

Содержание 19590

Страница 1: ...arge of 1000 V down to 100 V in less than one second at a distance of six inches 30 psi 0 2MPa inlet pressure Refer to the ESD Association ANSI ESD Standard STM3 1 for the test procedure The offset voltage balance is within 30 V of zero at a distance of six inches significantly less than the required limits of 50 volts per ANSI ESD S20 20 Necessary non conductors in the environment cannot lose the...

Страница 2: ... Figure 4 19592 optional foot switch should be connected to the ion gun console Letter C in Figure 3 Installation COMPRESSED GAS REQUIREMENTS NOTE Failure to use clean dry air or nitrogen may result in damage to the Chargebuster Ion Gun that is not covered under the Limited Warranty The compressed gas supply must be clean dry air or nitrogen supplied by a delivery system that utilizes a refrigerat...

Страница 3: ... the console directly to the gas supply pipe or attach it using a hose not supplied If necessary use a prefilter as defined in the COMPRESSED GAS REQUIREMENTS section of this technical bulletin IV If you would like to use the optional foot switch plug its cable to the jack located at the top of the console Operation NOTE Our recommendation is to set the pressure regulator on your air or nitrogen s...

Страница 4: ...egins to look dirty I Turn power off at the console and disconnect the console from the gas supply II Hold down the disposable filter release button on the side of the console III Remove the hose and disposable filter from the console by pulling the textured rubber plug where the hose emerges from the console Rocking the plug back and forth can help loosen the filter Do not pull the hose itself IV...

Страница 5: ...rranty call Customer Service at 909 627 8178 Chino CA or 781 821 8370 Canton MA for a Return Material Authorization RMA and proper shipping instructions and address Desco Charleswater will quote repair charges necessary to bring your unit up to factory standards Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHA...

Отзывы:

Похожие инструкции для 19590