background image

TB-3033

 May 2012 Page 1 of 5

Chargebuster Ion Gun

Installation, Operation and Maintenance

Figure 1. Desco 

19590

 Chargebuster Ion Gun, 120V

Description

The Desco 

19590

 Chargebuster Ion Gun is a Point-of-Use 

Ionizer.  It uses compressed air or nitrogen to neutralize 

static charges in localized areas.  Most companies 

address ElectroStatic Attraction, visual imperfections, 

and contamination issues by dislodging charged dust and 

debris with compressed air ionizers.  “There is sometimes 

a need to provide static control in a small defined area or 

location. This may be done to provide static control within 

production equipment, in mini-environments, or to facilitate 

particle removal from part of a product. Ionizers used for 

this purpose may be blow-off guns or nozzles that work 

with a supply of compressed air or nitrogen. They may use 

either nuclear, soft x-ray or any of the previously described 

types of corona ionization technology. It will be important 

to choose a method of ionization and cleanliness of the 

gas supply that is appropriate to the work area.”  (ESD 

handbook ESD TR20.20 section 5.3.6.5.2.4 Point-Of-Use 

Ionization)
The modular and ergonomic design includes an ESD 

protective flexible hose and is easily controlled by 

depressing the trigger.  The Desco 

19590

 Chargebuster 

Ion Gun meets or exceeds the required limits of ANSI/ESD 

S20.20 when tested in accordance with ANSI/ESD S3.1 and 

ESD TR53.
Compact and lightweight, the Chargebuster Ion Gun’s 

console can be mounted anywhere on the workstation for 

easy access.  The console connects to any supply of clean 

dry air or nitrogen, and an internal disposable filter collects 

residual particles, oil and moisture.  The console, gun, and 

air hose are static-dissipative.  The 7 foot hose allows for 

convenient neutralization of localized areas where desired.

© 2011 DESCO INDUSTRIES INC.

Employee Owned

The Chargebuster Ion Gun reduces a static charge of 

±1000 V down to ±100 V in less than one second at a 

distance of six inches (30-psi /0.2MPa inlet pressure).  

Refer to the ESD Association ANSI/ESD Standard STM3.1 

for the test procedure.  The offset voltage (balance) is 

within ±30 V of zero at a distance of six inches, significantly 

less than the required limits of < ±50 volts per ANSI/ESD 

S20.20.
“Necessary non-conductors in the environment cannot 

lose their electrostatic charge by attachment to ground. 

Ionization systems provide neutralization of charges on 

these necessary non-conductive items (circuit board 

materials and some device packages are examples of 

necessary non-conductors). Assessment of the ESD 

hazard created by electrostatic charges on the necessary 

nonconductors in the work place is required to ensure 

that appropriate actions are implemented, commensurate 

with risk to ESDS [ESD sensitive] items”. (ANSI/

ESDS20.20-2007 Foreword)
“The primary method of static charge control is direct 

connection to ground for conductors, static dissipative 

materials, and personnel. A complete static control program 

must also deal with isolated conductors that cannot be 

grounded, insulating materials (e.g., most common plastics), 

and moving personnel who cannot use wrist or heel straps 

or ESD control flooring and footwear. Air ionization is not 

a replacement for grounding methods. It is one component 

of a complete static control program. Ionizers are used 

when it is not possible to properly ground everything and as 

backup to other static control methods. In clean rooms, air 

ionization may be one of the few methods of static control 

available.” (ESD Handbook TR20.20 Ionization, section 

5.3.6.1)

Packaging

1 Chargebuster Ion Gun with Hose

19591

 Air Filter

1 Power Adapter (120VAC in, 24VAC out)

1 10' Cable

1 Mounting Plate

1 Quick Coupling

1 S-Hook

4 Screws

1 Certificate of Calibration

Use replacement filter Item #

19591

 and 

Use foot switch Item #

19592

 

DESCO WEST

 - 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

 - One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Fax (781) 575-0172 • Website: 

Desco.com

TECHNICAL BULLETIN TB-3033

Содержание 19590

Страница 1: ...arge of 1000 V down to 100 V in less than one second at a distance of six inches 30 psi 0 2MPa inlet pressure Refer to the ESD Association ANSI ESD Standard STM3 1 for the test procedure The offset voltage balance is within 30 V of zero at a distance of six inches significantly less than the required limits of 50 volts per ANSI ESD S20 20 Necessary non conductors in the environment cannot lose the...

Страница 2: ... Figure 4 19592 optional foot switch should be connected to the ion gun console Letter C in Figure 3 Installation COMPRESSED GAS REQUIREMENTS NOTE Failure to use clean dry air or nitrogen may result in damage to the Chargebuster Ion Gun that is not covered under the Limited Warranty The compressed gas supply must be clean dry air or nitrogen supplied by a delivery system that utilizes a refrigerat...

Страница 3: ... the console directly to the gas supply pipe or attach it using a hose not supplied If necessary use a prefilter as defined in the COMPRESSED GAS REQUIREMENTS section of this technical bulletin IV If you would like to use the optional foot switch plug its cable to the jack located at the top of the console Operation NOTE Our recommendation is to set the pressure regulator on your air or nitrogen s...

Страница 4: ...egins to look dirty I Turn power off at the console and disconnect the console from the gas supply II Hold down the disposable filter release button on the side of the console III Remove the hose and disposable filter from the console by pulling the textured rubber plug where the hose emerges from the console Rocking the plug back and forth can help loosen the filter Do not pull the hose itself IV...

Страница 5: ...rranty call Customer Service at 909 627 8178 Chino CA or 781 821 8370 Canton MA for a Return Material Authorization RMA and proper shipping instructions and address Desco Charleswater will quote repair charges necessary to bring your unit up to factory standards Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHA...

Отзывы:

Похожие инструкции для 19590