H. 4mm Parking Snap:
When touched by the operator,
this snap will deactivate the alarm for six seconds. This
allows time for the operator to disconnect the coil cord from
the wrist band and park it on this snap. While parked, the
coil cord disables the alarm, allowing the operator to leave
the workstation. The OPERATOR GROUND LED will
remain off while the cord is parked. Upon returning and
removing the coil cord from the parking snap, the operator
has six seconds to hook up to the wrist band before the
alarm sounds.
I. Monitored Operator Jack:
Where the operator inserts the
wrist cord plug.
Installation
Remove the monitor from its packaging and inspect for
any shipping damage. Confirm that the worksurface is
10 megohms or less and has a conductive layer such as
Dual Layer Rubber, Dissipative 3-Layer Vinyl, or Micastat®
Dissipative Laminate with conductive buried layers.
1. Locate a nearby power outlet and test it for proper wiring
and grounding. We recommend the
Desco AC Outlet
Analyzer
to verify proper wiring and ground.
2. Connect the tinned wire termination of the Ground Cord
to the GND terminal block on the monitor.
3. Connect the tinned wire termination of the Mat Monitor
Cord to the MAT terminal block on the monitor.
4. Determine the mounting location of the Full-Time
Continuous Monitor. It is normally installed toward the
front edge of a workstation where its LEDs can be visible
to the operator. Use the included hook and loop strip if
desired.
5. Use a blade to pierce two holes 12" to 72" apart from
one another into the worksurface mat.
6. Use a Phillips screwdriver to secure the two flathead
screws and countersunk washers through the
worksurface mat and into the threaded 10mm snaps on
the underside of the Mat Monitor Cord and Ground Cord.
7. Connect the power cord to the power inlet located on the
top-side of the Full-Time Continuous Monitor. Connect
the opposite end of the power cord to the tested AC
outlet.
NOTE: Older revision Full-Time Continuous Monitors
included push and clinch snaps instead of countersunk
washers and flat head screws to secure the mat monitor cord
and ground cord to the worksurface mat.
Figure 4. EMIT
50547
Full-Time Continuous Monitor
Relay Box
50547 RELAY BOX
Figure 3. Wiring the Full-Time Continuous Monitor to a
worksurface mat
Must be 12-72" apart
The Full-Time Continuous Monitor can be equipped with
the EMIT
50547
Relay Box to control electronic door locks,
lights, buzzers, etc. The relay will activate when a failure is
caught by the Full-Time Continuous Monitors.
Maximum Switching Current:
1A @ 30VDC or .3A @ 125VAC
Contact Form:
2 Form C