TB-6534
Page 5 of 8
Revision 4/06
© 2006 DESCO INDUSTRIES INC.
Employee Owned
2
5 4 A
The first digit of the address will be flashing. Press
T
or
S
buttons to change
J
J
J
J
the first digit (0 to 2). Press the
W
button to go to the enable or disable remote
W
T
S
X
menu.
O F F r
After pressing the
W
button to get to the enable or disable remote menu the
J
J
J
J
display will show “
OFF r
” for remote off (default setting). This means that the unit
W
T
S
X
will not respond to the remote control. To enable the remote, press the
T
or
S
buttons until the display reads “
On r
” for remote on.
Alarm Conditions
The ionizer is able to detect various problems that may occur through normal use. The
unit can detect low and high line voltages, and inoperable high voltage power modules. The
unit will sound a continuous audible alarm during all alarm conditions.
A C L
If the unit detects that the AC line voltage is too low, it will display “
AC L
” and
J
J
J
J
sound the alarm. If the unit detects that the line voltage is too high, it will
W
T
S
X
display
“
AC H
” and sound the alarm.
S H d 1
If the unit detects that there is something wrong with the high voltage modules, or
J
J
J
J
the sensor circuitry, it will shutdown the high voltage modules of the fan for which
W
T
S
X
it detected the problem. If this occurs for fan #1 the unit will display
“
SHd 1
” and sound the alarm.
Maintenance / Cleaning Procedure
WARNING – RISK OF ELECTRIC SHOCK –
These servicing instructions are for use
by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing
of internal parts unless you are qualified to do so.