background image

111252-01B

For more information, visit www.desatech.com

For more information, visit www.desatech.com

10

Horizontal High
Wind Square
Termination

Wall Firestop

45° Elbow

Figure 14 - Horizontal Termination Configuration for Square or
Round Terminations

45° Elbow

Wall
Firestop

Horizontal
Round
Termination

Exterior Portion of Wall
Firestop (Round
Termination Only)

GROUND FLOOR INSTALLATION

Recommended Applications:

• Installation using cabinet surrounds

• Through the wall using round or square termination

(up to 12" horizontal pipe)

• NOT FOR CORNER INSTALLATION

VENTING INSTALLATION
INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

Adjustable
Pipe 12" Max.

Horizontal Termination Configurations

Figures 14 through 18 show different configurations and alternatives
for venting with horizontal termination. Each figure includes a chart
with critical minimum and maximum dimensions which MUST be
met. 

IMPORTANT: 

Remember that a horizontal run of venting must

have a 1/4" rise for every 12" of run toward the termination.

Figure 13 - Typical Horizontal Termination Cap Mounting with
Additional Siding Standoff Installed

Siding Standoff

Screws

High Wind
Termination

Apply Mastic to
Outside Edge of
Standoff

Exterior Wall
with Vinyl Siding

10 

3

/

4

" x 10 

3

/

4

"

Framed
Opening

Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall

Minimum Pipe
Overlap 1

1

/

4

"

Wall
Firestop

Direct Vent
Pipe

 WARNING: Never run vent downward as this may

cause excessive temperatures which could cause a
fire. Operation of improperly installed and main-
tained venting system could result in serious injury,
property damage or loss of life.

9.

Combustible Exterior Wall Only:

 Slide wall firestop against

interior wall surface and attach with screws provided. See Figure
13 for horizontal termination details.

10. Place fireplace into position and shim with noncombustible ma-

terial if needed. Nail or screw side flanges to framing to secure
unit in place. 

IMPORTANT:

 Make sure fireplace is level before

securing. If fireplace is not level it will not work properly.

Round Termination
(Kit 01491 for V36 Series Kit
SDHTRK-58 for CHDV Series)

Square Termination

Vertical (V)

Horizontal (H)

32 

3

/

4

" min.

17" max.

NOTICE: Do not seal termination cap to vent pipe.
Cap must be removable for vent inspection and
maintenance.

Содержание VV36NA1 SERIES

Страница 1: ...ppliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING If the information in this...

Страница 2: ...nting system Itbringsinfreshairforcombustionthroughtheouterpipeand combustion gases are exhausted through the inner pipe If the glass door assembly and venting pipe are not properly seated connected a...

Страница 3: ...fireplace to cook food or burn paper or other objects 13 Do not use any solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nameplate 14 This appli...

Страница 4: ...ocation for your fireplace and termination cap When deciding the location of your fireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel bur...

Страница 5: ...ight above the fireplace Note Noncombustible mantels may discolor PRE INSTALLATION PREPARATION Continued NOTICE This fireplace is intended for use as supple mental heat Use this fireplace along with y...

Страница 6: ...nlet 72 inches 182 9cm minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum...

Страница 7: ...tic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination VENTING INSTALLATION INSTRUCTIONS NOTICE Read these instructions completely be fore attempting installa...

Страница 8: ...slots on the male ends of adjacent pipes Push pipe sections together and twist one section clockwise approxi mately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal ru...

Страница 9: ...standoff Bolt the vent cap to the stand off Apply non hardening mastic around outside edge of stand off Position the standoff cap assembly in the center of the 10 3 4 square hole and attach to exteri...

Страница 10: ...l Horizontal Termination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Screws High Wind Termination Apply Mastic to Outside Edge of Standoff Exterior Wall with Vinyl Siding 10...

Страница 11: ...l rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on the exterior o...

Страница 12: ...ce Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max Figure 17 Horizontal T...

Страница 13: ...above is a room install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow conn...

Страница 14: ...Elbow Vertical V Horizontal H 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Figure 22 Vertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown Note...

Страница 15: ...nstallation Parts Lists for Venting Kits and Components for V36 and VV36 Series PARTS LISTS FOR VENTING KITS AND COMPONENTS FOR V36 AND VV36 SERIES DESA 5 8 Pipe Vent Kits Number Description P58 6 6 S...

Страница 16: ...and Components for V36 and VV36 Series Cont Parts Lists for Venting Kits and Components for VV361 Model Series Parts Lists for Venting Kits and Components for CHDV Model Series PARTS LISTS FOR VENTING...

Страница 17: ...in the switch bracket see Figure 26 Figure 25 Blower Model BK Magnetic Strips Exhaust Port Screw Green Ground Wire Spade Terminals Figure 26 Attaching Speed Control to Firebox Speed Control Control S...

Страница 18: ...of the firebox outer wrapperwiththeexhaustportdirectedupwardandthethermodisc positioned up near the fireplace bottom The thermodisc must be oriented near the fireplace bottom as shown in Figure 28 in...

Страница 19: ...tion must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from fireplace see Figure 31 IMPORTANT Install ma...

Страница 20: ...f the access holes on side of fireplace 3 Attach flexible gas line from gas supply to control valve see Figure 32 4 Check all gas connections for leaks See Checking Gas Connections Figure 32 Connectin...

Страница 21: ...rminal Wires Battery Clip Figure 36 Connecting Wall Swith to Control Valve INSTALLING OPTIONAL WALL MOUNT SWITCH GWMS2 1 Connect one terminal of 25 ft wire for the wall switch to the TPTH terminal on...

Страница 22: ...ar gloves and tape the remaining fragments onto the frame 1 Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen rod assembly from the firebox Set...

Страница 23: ...ce carefully remove logs lava rock and ember material 4 Remove three screws from deflector shield on the inside top of firebox Set shield and screws aside 5 Install rear brick panel first Rest bottom...

Страница 24: ...nstructions for fireplace model numbers 1 Place log 1 base log onto pin on left front side of grate as shown in Figure 45 2 Restleftsideoflog 2 frontlog ontotopoflog 1 Placerightside oflogontosecondpi...

Страница 25: ...ghtly and turn clockwise to OFF 5 Close lower louver panel Shutting Off Burners Only pilot stays lit You may shut off the burners and keep the pilot lit by doing one of the following 1 Turn gas contro...

Страница 26: ...Fahrenheit Centigrademodedisplay carefullypressthe C Fmodebuttonwiththeendofapapercliporsimilarbluntobject Manual Mode 1 Press the POWER and LOCK buttons together to turn on the hand held remote contr...

Страница 27: ...lame from the pilot burner must extend beyond both the thermocouple and thermopile If you pilot assembly does not meet these requirements turn fireplace off see To Turn Off Gas to Appliance page 25 se...

Страница 28: ...emove if glass is hot Keep children and pets away from glass WARNING Donotoperatefireplacewiththeglass door removed cracked or broken WARNING Turn off fireplace and let cool before cleaning CAUTION Yo...

Страница 29: ...y or partially clogged pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any me...

Страница 30: ...burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Mainte nance page 28 or replace burner orifice 1 Adjust the log...

Страница 31: ...ial OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark residue on logs or inside of firepl...

Страница 32: ...TRATED PARTS BREAKDOWN Models V V36NA 1 V V36NSA 1 V V36NHA 1 V V36PA 1 V V36PSA 1 V V36PHA 1 and CHDV36NRA ILLUSTRATED PARTS BREAKDOWN MODELS V V36NA 1 V V36NSA 1 V V36NHA 1 V V36PA 1 V V36PSA 1 V V3...

Страница 33: ...09082 01 109082 01 109082 01 109082 01 Heat Shield 1 10 ___ See Below See Below See Below Left Refractory Brick Panel 1 11 ___ See Below See Below See Below Rear Refractory Brick Panel 1 12 ___ See Be...

Страница 34: ...4 4 3 2 5 6 7 8 9 10 11 12 13 14 15 16 17 1 21 19 20 18 ILLUSTRATED PARTS BREAKDOWN BURNER ASSEMBLY FOR MODELS V V36NA 1 V V36NSA 1 V V36NHA 1 V V36PA 1 V V36PSA 1 V V36PHA 1 CHDV36NRA ILLUSTRATED PAR...

Страница 35: ...Fitting 1 11 14554 Tubing Assembly 1 12 14500 Brass Fitting 1 13 14389 Millivolt Valve Natural Gas 1 14390 Millivolt Valve Propane LP Gas 1 14 14253 Flexible Gas Line 1 15 11107 Screw 10 32 x 1 4 PPH...

Страница 36: ...feel your gas pressure is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting If so contact DESA s Customer...

Страница 37: ...Completed College Completed Graduate School 13 Age of Purchaser Under 20 20 29 30 39 40 49 50 59 60 or Over 14 Buyer s total annual household income Under 15 000 15 000 to 19 999 20 000 to 34 999 35...

Страница 38: ...111252 01B For more information visit www desatech com For more information visit www desatech com 38 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Postage Required TAPE TAPE...

Страница 39: ...ES LOUVER TRIM KIT Rolled Louvers Only Not Shown LT36B Rolled Louver Trim Kit Brushed Brass LT36P Rolled Louver Trim Kit Platinum LT36PB Rolled Louver Trim Kit Polished Brass DEFLECTION HOODS Not Show...

Страница 40: ...ansportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE...

Отзывы: