www.desatech.com
116292-01E
18
troubleshootING
WARNING: Turn off and unplug heater and let cool before servicing.
Only a qualified service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note:
All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor electrode positioned
wrong
2. Ignitor electrode broken
3. Ignitor electrode not con
-
nected to ignitor cable
4. Ignitor cable pinched or wet
5. Broken ignitor cable
6. Bad ignitor
1. Gas supply turned off or equip
-
ment shutoff valve closed
2. Control knob not in PILOT
position
3. Control knob not pressed in
while in PILOT position
4. Air in gas lines when in
-
stalled
5. Depleted gas supply (propane/
LP gas only)
6. ODS/pilot is clogged
7. Gas regulator setting is not
correct
OBSERvED PROBLEM
When ignitor button is pressed,
there is no spark at ODS/pilot
When ignitor button is pressed,
there is spark at ODS/pilot but
no ignition
REMEDY
1. Replace pilot assembly
2. Replace pilot assembly
3. Reconnect ignitor cable
4. Free ignitor cable if pinched
by any metal or tubing. Keep
ignitor cable dry
5. Replace ignitor cable
6. Replace ignitor
1. Turn on gas supply or open
equipment shutoff valve
2. Turn control knob to PILOT
position
3. Press in control knob while in
PILOT position
4. Continue holding down con
-
trol knob. Repeat igniting op
-
eration until air is removed
5. Contact local propane/LP gas
company
6. Clean ODS/pilot (see
Cleaning
and Maintenance
, page 17) or
replace ODS/pilot assembly
7. Replace gas regulator