background image

www.desatech.com

108796-01T

2

  WARNING:  Improper  installation,  adjustment,  al

-

teration,  service  or  maintenance  can  cause  injury  or 
property damage. Refer to this manual for correct in

-

stallation and operational procedures. For assistance 

or  additional  information  consult  a  qualified  installer, 

service agency or the gas supplier.

NOT FOR USE WITH SOLID FUEL

CHECK LOCAL CODES PRIOR TO INSTALLATION

SAVE THIS BOOK

This book is valuable. In addition to instructing you on 
how to install and maintain your appliance, it also con

-

tains information that will enable you to obtain replace

-

ment parts or optional accessory items when needed. 
Keep it with your other important papers.

This appliance may be installed in an aftermarket*, per

-

manently located, manufactured (mobile) home, where 
not prohibited by state or local codes.
This appliance is only for use with the type of gas indi

-

cated on the rating plate.

This  appliance  is  not  convertible  for  use  with  other 
gases, unless a certified kit is used.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

State of Massachusetts: The installation must be made 
by a licensed plumber or gas fitter in the Commonwealth 

of Massachusetts.

table oF CoNteNts

Safety .................................................................. 3
Unpacking............................................................ 4
Introduction .......................................................... 4
Selecting Location ............................................... 5

Product Specifications

 ......................................... 6

PreInstallation Preparation

 .................................. 7

Venting Installation

 .............................................. 9

Installation

 ..........................................................11

Operation ........................................................... 18

Inspecting Burners

............................................. 19

Cleaning and Maintenance ................................ 20

Replacement Parts

 ............................................ 20

Wiring Diagram .................................................. 21

Service Hints

 ..................................................... 21

Technical Service............................................... 21

Troubleshooting

 ................................................. 22

Parts

 .................................................................. 24

Accessories

 ....................................................... 29

Warranty ..............................................

Back Cover

Содержание VM36E(B

Страница 1: ...ot try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you...

Страница 2: ...e may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by state or local codes This appliance is only for use with the type of gas indi cated on the ra...

Страница 3: ...ating plate This appliance is not convertible for use with other gases unless a certified kit is used 2 For propane LP fireplace do not place propane LP supply tank s inside any structure Locate propa...

Страница 4: ...ped on cardboard Three 3 plastic bags containing lava rock pan and ember materials Rear Log Remove two plastic quick ties from around burner and grate Grate Stand Lift off of burner pan Check all item...

Страница 5: ...piping system at test pressures equal to or less than 1 2 psig 3 5 kPa For the purpose of input adjustment two pressure taps for IN and OUT pressures are provided on the gas control valve for test ga...

Страница 6: ...66 kPa 10 5 WC 2 66 kPa Orifice Size 30 29 GAS RATING PROPANE LP M36P B H VM36P B H M42P B H VM42P B H Max Input Rating 40 000 Btu Hr 45 000 Btu Hr Manifold Pressure 10 WC 2 49 kPa 10 WC 2 49 kPa Min...

Страница 7: ...ts in relation to fireplace opening Spacer 3 7 6 cm 1 1 2 3 8 cm Max B 6 15 2 cm A 12 22 9 cm Combustible Materials Header Figure 5 Mantel Clearances Side View Cross Section 1 1 2 3 8 cm Max 3 7 6 cm...

Страница 8: ...k iron pipe does not mate with fitting at the end of flexible gas line remove fitting and replace with a 37 degree flare 3 4 12 1 2 NPT female fitting WARNING When finishing appliance do not overlap c...

Страница 9: ...terminate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing roof jack or a roof thimble At all points the listed clearances must be maintained Ve...

Страница 10: ...installation It is not recommended that this appliance be common vented with an existing gas burning appliance However if it becomes necessary to common vent this appliance the venting system must be...

Страница 11: ...Control Receiver Extension Cord Ignition Module Plug NOTICE This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in the case of aventingproblem Donotbypass...

Страница 12: ...LLC recommends that a black iron gas line be routed from the gas source through a sediment trap shown in Figure 18 and into appliance Once connected through appliance a flexible gas line may be used...

Страница 13: ...pear leaks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected Installation Continued Complete your gas installation by connect ing...

Страница 14: ...into notch on left of log 2 see Figure 25 Rest lower end of log 5 on grate as shown in Figure 26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper en...

Страница 15: ...Place upper end of log 5 into notch on top inner right of log 1 see Figure 29 Rest lower end of log 5 on middle grate finger as shown in Figure 30 6 Place log 6 into notch on top right of log 1 see Fi...

Страница 16: ...Sealing Between Appliance and Framing Installing optional GLASS DOOR Accessory CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for some individuals If t...

Страница 17: ...s free of clip 2 Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail see Figure 35 CAUTION Always operate the appliance with the do...

Страница 18: ...off Valve Adjustment Screw FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss...

Страница 19: ...ure to press ON OFF buttons on hand held remote control unit for up to 3 seconds to assure proper operation 2 Press the ON OFF button to turn burner on and off Check pilot flame pattern and burner fla...

Страница 20: ...dust dirt or lint logs If you remove logs for cleaning refer to log placement information on page 12 to properly replace logs Use a vacuum cleaner to remove any carbon buildup on logs Replace log s i...

Страница 21: ...e Wiring Diagram Service Hints When Gas Pressure Is Too Low pilot will not stay lit burner will have delayed ignition fireplace will not produce specified heat propane LP gas supply may be low if usin...

Страница 22: ...tage REMEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air out of lines If after repeated attempts applianc...

Страница 23: ...ne LP gas low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2...

Страница 24: ...EP B H M42E B H M42EP B H VM36E B H VM36EP B H VM42E B H and VM42EP B H 51 21 1 10 11 6 50 50 22 3 8 20 9 52 13 43 14 45 48 62 44 40 23 4 39 17 2 42 41 9 55 7 46 19 47 7 47 18 5 16 12 15 52 33 31 28 3...

Страница 25: ...flector 1 25 11165 11165 Screw 10 x 5 8 2 26 107796 01 107796 02 Grate Assy 1 27 107742 01 107742 02 Burner Pan 1 28 107795 01 107831 01 Burner Tube 1 29 107748 01 107748 01 Burner Brckt 1 30 107985 0...

Страница 26: ...42EH 1 106660 01 107816 01 Rear Refractory Std Brick VM36EB VM42EB 1 108166 01 108171 01 Rear Refractory Herringbone VM36EH VM42EH 1 15 106661 02 107818 02 Bottom Rear Refractory Std Brick M36 ME42 M3...

Страница 27: ...d VM36P B H KEY NO PART NO DESCRIPTION QTY 107999 01 Log Set 1 108724 01 Right Front 9 Split Log 1 2 901098 01 Rear Log 1 3 108720 01 Top Right Log 11 3 4 1 4 108721 01 Top Right Log 16 1 5 108722 01...

Страница 28: ...1 Left Front Log 11 1 2B 108839 01 Right Front Log 15 3 4 Round 1 3 108722 01 Top Left Log 13 1 2 Y Log 1 4 108838 01 Inside Top Left Log 15 3 4 Split 1 5 108721 01 Inside Top Right Log 16 1 6 108720...

Страница 29: ...and M42P B H BL36 36 Refractory Standard Brick BL42 42 Refractory Standard Brick BL36H 36 Refractory Herringbone Brick BL42H 42 Refractory Herringbone Brick For VM36 B H VM36P B H VM42 B H and VM42P...

Страница 30: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 31: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...