background image

www.desatech.com

108795-01V

21

INsPeCtING burNers

Continued

BURNER FLAME PATTERN

Burner flames will be steady, not lifting or float-
ing. Flames should go up through the middle 
of logset. Flames should not "spill" to edges 
of pan or sides of logset.

Thermopile

Pilot 
Burner

Ignitor

Figure 42 - Correct Pilot Flame Pattern

Figure 43 - Typical Flame Pattern

CleaNING aNd maINteNaNCe

Figure  43  shows  a  typical  flame  pattern.  If 
burner  flame  pattern  differs  from  that  de-
scribed:
•  turn appliance off (see 

To Turn Off Gas to 

Appliance

, page 20) 

•  see 

Troubleshooting

, page 23

 WARNING: Installation and 

repair should be done by a quali

-

fied service person. The appli

-

ance should be inspected before 

each use and at least annually 

by  a  qualified  service  person. 

More frequent cleaning may be 

required  due  to  excessive  lint 

from  carpeting,  bedding  mate

-

rial, pet hair, etc. It is imperative 

that the control compartments, 

burners and circulating air sys

-

tem be kept clean.

 WARNING: The logs can be 

hot. Handle only when cool.

 WARNING: Turn off gas and 

electrical power before servicing 

appliance.

  WARNING:  Failure  to  keep 

the  primary  air  opening(s)  of 

the burner(s) clean may result in 

sooting and property damage.

PILOT AND BURNER

•  Remove  logs  and  ember  material  before 

cleaning burner and replace when cleaning 
is complete.

•  Burner  and  controls  should  be  cleaned 

with  compressed  air  to  remove  dust,  dirt 
or lint.

•  Use a vacuum cleaner or small, soft bristled 

brush to remove excess dust, dirt or lint.

LOGS

•  If  you  remove  logs  for  cleaning,  refer  to 

log placement information on page 12 to 
properly replace logs.

•  Use  a  vacuum  cleaner  to  remove  any 

carbon buildup on logs.

•  Replace log(s) if broken. See 

Replacement 

Parts

, page 22.

•  Replace  ember  material  periodically  as 

needed. See 

Replacement Parts

, page 22.

Содержание VM36B

Страница 1: ...t any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach...

Страница 2: ...e may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by state or local codes This appliance is only for use with the type of gas indi cated on the ra...

Страница 3: ...to excessive lint and dust from carpeting bedding material etc Turn off the gas valve and pilot light before cleaning fireplace 10 Have venting system inspected annually by a qualified service person...

Страница 4: ...ms are packed inside the firebox Remove before positioning firebox into framing Transition Collar For vent connection Ceramic Log Pack Shrink wrapped on cardboard Three 3 plastic bags containing lava...

Страница 5: ...sting ofthegassupplypipingsystemattestpressures equal to or less than 1 2 psig 3 5 kPa For the purpose of input adjustment two pressure taps for IN and OUT pressures are provided on the gas control va...

Страница 6: ...ximum Supply Pressure 13 WC 3 23 kPa 13 WC 3 23 kPa Orifice Size 52 51 S T P Q R X Outside Air Kit Location Optional K 7 J I M L V 13 5 1 5 Glass Door Optional W O N Alternate Gas Supply Inlet 7 G H F...

Страница 7: ...le components in relation to fireplace opening Spacer 3 7 6 cm 1 1 2 3 8 cm Max B 6 15 2 cm A 12 22 9 cm Combustible Materials Header Figure 5 Mantel Clearances Side View Cross Section M36 B H M36P B...

Страница 8: ...to the flexible gas line Note If 1 2 NPT black iron pipe does not mate with fitting at the end of flexible gas line remove fitting and replace with a 37 flare 3 4 12 1 2 NPT female fitting WARNING Wh...

Страница 9: ...minate vertically into a listed type vent cap and extend a sufficient height through an approved roof flashing roof jack or a roof thimble At all points listed clearances must be maintained Vent termi...

Страница 10: ...nspected for damage and proper installation It is not recommended that this appliance be common vented with an existing gas burning appliance Note Before connecting this appliance to an existing vent...

Страница 11: ...E This appliance is equipped with a vent safety shutoff switch which will shut down the appliance in the case of a venting problem Do not bypass the vent safety switch If theapplianceshouldshutdown co...

Страница 12: ...g optional wireless hand held remote control the wall switch is no longer operational Installing Receiver 1 Remove front refractory access panel by lifting up and angling out of firebox open ing see F...

Страница 13: ...and Held Remote Control Unit Battery Cover 9 Volt Battery Terminal Wires Remote Control Unit Battery Housing Installation Continued DESAHeating LLC recommends that a black iron gas line be routed from...

Страница 14: ...ear leaks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected Installation Continued Complete your gas installation by connect ing i...

Страница 15: ...5 into notch on left of log 2 see Figure 27 Rest lower end of log 5 on grate as shown in Figure 28 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 28 and position upper...

Страница 16: ...e upper end of log 5 into notch on top inner right of log 1 see Figure 31 Rest lower end of log 5 on middle grate finger as shown in Figure 32 6 Place log 6 into notch on top right of log 1 see Figure...

Страница 17: ...tion Figure 34 Sealing Between Appliance and Framing Installing optional GLASS DOOR Accessory CAUTION Use only glass doors certified for use with this appliance Note Glass door may be heavy for some i...

Страница 18: ...pin is free of clip 2 Fully fold frame assembly and slide upper edge towards center of firebox opening until guide pins are free of frame rail see Figure 37 CAUTION Always operate the appliance with t...

Страница 19: ...l Knob in the PILOT position Position Indicator Gas Control Knob Pilot Adjustment Screw FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosio...

Страница 20: ...remote control unit IMPORTANT Do not leave selector switch in the REMOTE or ON position when pilot is not lit This will drain the battery 2 Press control button on hand held remote to turn burner on...

Страница 21: ...to excessive lint from carpeting bedding mate rial pet hair etc It is imperative that the control compartments burners and circulating air sys tem be kept clean WARNING The logs can be hot Handle onl...

Страница 22: ...t part number Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Parts Under Warranty Contact authorized dealers of this product If the...

Страница 23: ...tch wires defective or too long 2 Thermopile not generating sufficient voltage 1 Pilot flame may be too low causing safety pilot to drop out 2 Improper venting or exces sive blockage REMEDY 1 Check to...

Страница 24: ...If no spark and electrode wire is properly connected replace ignitor 2 Using a match light pilot If pilot lights turn off pilot and trigger the red button again If pilot lights an improper gas air mi...

Страница 25: ...LP gas low fuel supply 3 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas...

Страница 26: ...odels M36 B H M36P B H M42 B H M42P B H VM36 B H VM36P B H VM42 B H and VM42P B H 43 21 1 10 11 6 8 8 22 25 13 4 14 45 17 3 44 40 39 41 42 9 7 46 19 47 7 47 20 5 16 12 15 25 33 31 28 32 27 11 24 18 38...

Страница 27: ...bly 1 23 20042 20042 Air Kit Cover 1 24 106948 02 107823 02 Smoke Deflector 1 25 20027 20027 Brick Liner Retainer 2 26 107796 01 107796 02 Grate Assembly 1 27 107742 01 107742 02 Burner Pan 1 28 10779...

Страница 28: ...6 02 108171 02 Rear Refractory Herringbone M36H M42H 1 106660 01 107816 01 Rear Refractory Std Brick VM36B VM42B 1 108166 01 108171 01 Rear Refractory Herringbone VM36H VM42H 1 15 106661 02 107818 02...

Страница 29: ...VM36P B H KEY NO PART NUMBER DESCRIPTION QTY 107999 01 Log Set 1 108724 01 Right Front 9 Split Log 1 2 901098 01 Rear Log 1 3 108720 01 Top Right Log 11 3 4 1 4 108721 01 Top Right Log 16 1 5 108722 0...

Страница 30: ...01 Left Front Log 11 1 2B 108839 01 Right Front Log 15 3 4 Round 1 3 108722 01 Top Left Log 13 1 2 Y Log 1 4 108838 01 Inside Top Left Log 15 3 4 Split 1 5 108721 01 Inside Top Right Log 16 1 6 10872...

Страница 31: ...For M36 B H M36P B H M42 B H and M42P B H BL36 36 Refractory Standard Brick BL42 42 Refractory Standard Brick BL36H 36 Refractory Herringbone Brick BL42H 42 Refractory Herringbone Brick For VM36 B H...

Страница 32: ...ns furnished with this product This warranty covers the cost of part s required to restore this product to proper operating condition and an allowance for labor when provided by a DESA Heating LLC Aut...

Отзывы: