26

4.  Remount  new  frame  at  hinge  with  five 

new screws before closing door. This will 
ensure seating of gasket.

5.  Close glass door frame. Lock latches by 

placing bar under tab on door and pushing 
down and back on latch (see Figure 42, 
page 25).

6.  Replace screen/rod assembly by revers

-

ing step 1, page 25.

7.  Replace  louvers  by  reversing  procedure 

under 

Removing Louver Panels, 

page 25.

Cleaning Glass Door

See 

Cleaning and Maintenance

 on page 31.

INSTALLING LAVA ROCK AND 
GLOWING EMBERS

It  is  very  important  to  keep  logs  exactly  as 
installed.  Do  not  modify  logs.  Only  use  log 
set designed for this fireplace.

 WARNING: Logs are unitized 

and not attached to the burner. 

Do not handle log assembly by 

top logs. Always pick up by the 

bottom.

Open  louvers,  remove  screen,  unlock  door 
latches and open glass door. See 

Removing 

Glass Door

, steps 1 and 2, page 25.

1.  Pull ember material apart into pieces no 

larger  than  a  dime.  Place  these  pieces 
loosely and sparingly directly onto exposed 
front section of burner (see Figure 43). This 
will create the glowing ember appearance 
as flame touches ember material. Do not 
block air slots by using too much ember 
material  in  one  area.  Do  not  block  pilot 
ports with embers. It is not necessary to 
use all of the ember material provided.

2.  Pour lava rock onto plenum but not onto 

flat burner. It is not necessary to use all 
of the lava rock provided.

NOTICE: Do not put lava rock on 

burner or under burner. Placing 

lava rock on burner will cause 

performance problems.

3.  Close glass door, lock door latches, replace 

screen and close louvers (see 

Removing 

Glass Door

, steps 5 through 7).

FIREPLACE INSTALLATION

Continued

  WARNING:  The  glass  door 

must be securely in place before 

running this fireplace. Do not run 

this fireplace if glass is missing 

or broken.

Figure 43 - Placing Ember Material on 

Burner

Ember Material

Plenum

INSTALLING BRICK LINER MODELS 
BL42DA(SA) AND BL42DHA(SA)

  WARNING:  If  fireplace  has 

been  running,  turn  off  unit.  Let 

cool before installing brick liner.

You may purchase brick liner from your local 
retailer or see 

Accessories

, page 42.

  CAUTION:  Always  handle 

brick  panels  with  two  hands. 

Do  not  force  brick  panels  into 

place. Excessive force will break 

brick panels.

1.  Remove top and bottom louvers to allow 

access to door latches.

2.  Unlock door latches and open glass door. 

See 

Removing Glass Door

, steps 1 and 

2, page 25.

3.  Carefully  remove  lava  rock  and  ember 

material.

4.  Remove andiron assembly from plenum 

by removing screws.

5.   Carefully  lift  logs  and  ember  pod  from 

burner

6.  Remove  screws  that  attach  plenum  to 

burner to remove plenum.

Andiron

Содержание VKC42N Series

Страница 1: ...or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any ph...

Страница 2: ...tive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this log set Improper use of this log set can cause serious injury or death from burns...

Страница 3: ...cessory not approved for use with this fire place WARNING This appliance is only for use with the type of gasindicatedontheratingplate Thisapplianceisnotconvertible for use with other gases unless a c...

Страница 4: ...as valve and pilot light before cleaning fireplace 6 Have venting system inspected annually by a qualified service person If needed have venting system cleaned or repaired See Cleaning and Maintenance...

Страница 5: ...ollow the venting instructions very carefully for either vertical or horizontal applications This fireplace may be installed in any room of your house provided all local codes and these installation i...

Страница 6: ...to prevent accidental blockage of venting system When using snow blowers do not direct snow towards vent termination area For horizontal installations above 2 000 feet it is recommended that a 12 exte...

Страница 7: ...Vent C B A D E F G Top of Louver Opening 3 2 1 4 5 6 7 Wall Figure 5 Framing Clearances for Corner Installation Ref Mantel Depth Ref Mantel from Top of Louver Opening 1 14 A 16 2 12 B 14 3 10 C 12 4 8...

Страница 8: ...US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L...

Страница 9: ...ate on the out side of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance Adirect vent appliance must have its own venting system...

Страница 10: ...on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent...

Страница 11: ...screws provided see Figure 11 Siding standoff must sit flush against exterior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horiz...

Страница 12: ...ired NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a...

Страница 13: ...commended Applications Installations requiring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for i...

Страница 14: ...or a horizontal system using two 90 elbows Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace 45 Elbow Venting with Two 90 Elbows Vert...

Страница 15: ...bove ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insula tion from falling into required clearance space If area above ceiling is a living space install...

Страница 16: ...High Wind Termination Shown 45 Elbow Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Note Install restrictor into inner c...

Страница 17: ...s for High Altitude models ending in HA are for installation above 4000 feet only These fireplaces are equipped with parts specific for higher altitudes When installing a non high altitude fireplace a...

Страница 18: ...r Roof Flashing 0 12 6 12 26 Screws VKC 58 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Termination 6 Pipe 90 Elbow 18 Screws HHTK 58 High Wind Round Hori...

Страница 19: ...upward Blower will fit inside back opening and be held in position against back wall by magnets see Figure 26 4 Be certain that all wire terminals are securely attached to terminals on blower motor a...

Страница 20: ...er cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connec tions DO NOT trim excessive length away Enable just enough to make all connect...

Страница 21: ...Fan Switch N O Green White On 110 115 V A C Blower Motor Black Off 1 2 Black Installing Gas Piping to Fireplace Location WARNING A qualified service person must connect fireplace to gas supply Follow...

Страница 22: ...trap drip leg in supply line as shown in Figure 32 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap...

Страница 23: ...as fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection...

Страница 24: ...t connected as shown switch will not work 2 Route 25 ft wire through openings pro vided on sides of burner system to a con venient location to mount your switch 3 Connect one bare wire end to each ter...

Страница 25: ...ving glass door or louvers Removing Louver Panels Remove top and bottom louver panels by simultaneously pulling both top end spring latches towards center of appliance until they are disengaged from l...

Страница 26: ...ck pilot ports with embers It is not necessary to use all of the ember material provided 2 Pour lava rock onto plenum but not onto flat burner It is not necessary to use all of the lava rock provided...

Страница 27: ...sonal injury or loss of life A This appliance is equipped with an igni tion device which automatically lights the pilot Do not light pilot by hand B BEFORE LIGHTING smell all around the appliance area...

Страница 28: ...ush in gas control knob slightly and turn clockwise to OFF 5 Close lower louver panel MANUAL LIGHTING PROCEDURE 1 Remove glass door see Removing Re placing Glass Door page 25 2 Follow steps 1 through...

Страница 29: ...te in the center of the room facing towards the fireplace Note Do not hold the hand held remote for a long time Body temperature will affect its operation in the AUTO mode Safety Features When away fr...

Страница 30: ...i tion blower will not operate Note for BKT Only If you are using BKT blower with optional thermostat wall mounted or remote control for fireplace your fireplace and blower will not turn on and off at...

Страница 31: ...eration Thereafter clean the glass two or three times during each heating season depending on the usage and circumstances present Refer to Removing Replacing Glass Door page 25 of this manual when rem...

Страница 32: ...ling Lava Rock and Glowing Embers page 26 to properly replace logs Use a vacuum cleaner to remove any carbon buildup on logs Replace log s if broken See Replacement Parts on page 37 Replace ember mate...

Страница 33: ...in stalled 5 Depleted gas supply pro pane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tub...

Страница 34: ...2 Clean burner see Clean ing and Maintenance page 31 or replace burner orifice 1 Clean burner see Clean ing and Maintenance page 31 or replace burner orifice 2 Replace damaged burner 3 Replace gas co...

Страница 35: ...og grate removal 2 Check vent configuration specifications see Venting Installation page 9 1 This is normal If noise is excessive contact qualified service person 1 Replace 9 volt batteries in receive...

Страница 36: ...eak See Warning statement above 2 Control valve defective 1 Gas leak See Warning statement above OBSERVED PROBLEM Fireplace produces un wanted odors Fireplace shuts off in use Gas odor even when contr...

Страница 37: ...If they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your heater how he...

Страница 38: ...www desatech com 116239 01K 38 Parts Models KC42N VKC42N KC42P and VKC42P Series 6 7 20 17 18 13 2 12 19 8 1 4 24 11 9 14 3 16 5 15 21 10 23 25 26 22...

Страница 39: ...02 Bottom Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 116542 01 Burner Assembly NG See page 40 1 116542 02 Burner Assembly LP...

Страница 40: ...www desatech com 116239 01K 40 PARTS Burner assembly models KC42N VKC42N KC42P AND VKC42P Series 7 15 10 12 1 12 2 3 13 9 11 21 22 TPTH TP TH 6 12 14 18 17 17 18 19 20 16 14 8 4 5...

Страница 41: ...11288 02 Flex Gas Line 1 10 108084 02 Pilot Assembly NG 1 108084 03 Pilot Assembly LP 1 108084 05 Pilot Assembly HA Models 1 11 14389 Natural Gas Valve 1 14390 Propane LP Gas Valve 1 117370 01 Natural...

Страница 42: ...your local dealer If they can not supply these accessories call DESAHeating LLC at 1 866 672 6040 for information You can also write to the address listed on the back page of this manual Brick Liner...

Страница 43: ...r off without leaving the comfort of your easy chair A wall mounted docking station is included Receiver and Hand Held on off Remote Control Kit HRC100 Series Allows the fireplace to be turned on and...

Страница 44: ...ns furnished with this product This warranty covers the cost of part s required to restore this product to proper operating condition and an allowance for labor when provided by a DESA Heating LLC Aut...

Отзывы: