 WARNING: This product contains and/or generates 

chemicals  known  to  the  State  of  California  to  cause 

cancer or birth defects, or other reproductive harm.

IMPORTANT: Read this owner’s manual carefully and 

completely before trying to assemble, operate, or service 

this fireplace. Improper use of this fireplace can cause 

serious  injury  or  death  from  burns,  fire,  explosions, 

electrical shock, and carbon monoxide poisoning.

 DANGER: Carbon monoxide poisoning may lead 

to death!

This fireplace must be installed by a qualified (certified or licensed) 

service person. It has a sealed gas combustion chamber that uses 

a coaxial pipe (pipe within a pipe and having the same center) 

venting system. It brings in fresh air for combustion through the 

outer pipe and combustion gases are exhausted through the inner 

pipe. If the glass door assembly and venting pipe are not properly 

seated, connected, and sealed, carbon monoxide leakage (spillage) 

can occur.

Carbon  Monoxide  Poisoning:

 Early signs of carbon monoxide 

poisoning resemble the flu, with headaches, dizziness, or nausea. 

If you have these signs, the fireplace may not have been installed 

properly. 

Get fresh air at once!

 Have fireplace inspected and ser-

viced by a qualified service person. Some people are more affected 

by carbon monoxide than others. These include pregnant women, 

people with heart or lung disease or anemia, those under the influ-

ence of alcohol, and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making 

agent is added to each of these gases. The odor helps you detect 

a gas leak. However, the odor added to these gases can fade. Gas 

may be present even though no odor exists.

Make  certain  you  read  and  understand  all  warnings.  Keep  this 

manual for reference. It is your guide to safe and proper operation 

of this fireplace.

 WARNING: Any change to this fireplace or its con

-

trols can be dangerous.

1.  This appliance is only for use with the type of gas indicated on 

the rating plate. This appliance is not convertible for use with 

other gases unless a certified kit is used.

2.  For propane/LP fireplace, do not place propane/LP supply 

tank(s) inside any structure. Locate propane/LP supply tank(s) 

outdoors. To prevent performance problems, do not use pro-

pane/LP fuel tank of less than 100 lb. capacity.

3.  If you smell gas

•  shut off gas supply

•  do not try to light any appliance

•  do not touch any electrical switch; do not use any phone in 

your building

•  immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier's instructions

•  if you cannot reach you gas supplier, call the fire department.

4.  Never install the fireplace 

•  in a recreational vehicle

•  in windy or drafty areas where curtains or other combustible 

(flammable) objects can make contact with the fireplace front

•  in high traffic areas

5.  This fireplace reaches high temperatures. Keep children and 

adults away from hot surfaces to avoid burns or clothing igni-

tion. Fireplace will remain hot for a time after shutdown. Allow 

surfaces to cool before touching.

6.  Carefully supervise young children when they are in the room 

with fireplace.

7.  Do not modify this fireplace under any circumstances. Any 

parts removed for servicing must be replaced prior to operating 

fireplace.

8.  Turn fireplace off and let cool before servicing, installing, or 

repairing. Only a qualified service person should install, ser-

vice, or repair this fireplace. Have fireplace inspected annually 

by a qualified service person.

9.  You must keep control compartments, burners, and circulating 

air passages clean. More frequent cleaning may be needed due 

to excessive lint and dust from carpeting, bedding material, etc. 

Turn off the gas valve and pilot light before cleaning fireplace.

10.  Have venting system inspected annually by a qualified service 

person. If needed, have venting system cleaned or repaired. See 

Cleaning and Maintenance

, page 24.

11.  Keep the area around your fireplace clear of combustible ma-

terials, gasoline, and other flammable vapor and liquids. Do 

not run fireplace where these are used or stored. Do not place 

items such as clothing or decorations on or around fireplace.

TAbLE OF CONTENTS

Safety Information ........................................................................2

Product Identification

 ....................................................................3

Local Codes..................................................................................3
Product Features ..........................................................................3
Pre-Installation Preparation ..........................................................4
Location of Termination Cap .........................................................6
Venting Installation Instructions ....................................................7
Fireplace Installation...................................................................14
Operating Fireplace ....................................................................21
Inspecting Burners......................................................................24

Cleaning and Maintenance .........................................................24
Troubleshooting ..........................................................................25
Replacement Parts .....................................................................28
Service Hints ..............................................................................28
Technical Service........................................................................28

Specifications

 .............................................................................28

Accessories ................................................................................29
Illustrated Parts Breakdown and Parts List.................................30
Warranty Information ................................................... Back Cover

Содержание VK36N SERIES

Страница 1: ...ured mobile home where not prohibited by state or local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING Iftheinformationinthismanualis not followed exactly a fire or explosion may result causing property damage personal injury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or an...

Страница 2: ...utdoors To prevent performance problems do not use pro pane LP fuel tank of less than 100 lb capacity 3 If you smell gas shut off gas supply do not try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions if you cannot reach you gas supplier call the fire dep...

Страница 3: ...erstand and enjoy your direct vent fireplace The venting system may be routed to the outside of your home in several ways It may vent through the roof vertical or it may vent to an outside exterior wall horizontal The vent pipe instal lation is very important to allow for proper operation You must follow the venting instructions very carefully for either vertical or horizontal applications This fi...

Страница 4: ...e your fireplace it is recommended that you maintain a minimum 18 above top of louver opening When locating termination cap it is important to observe the minimum clearances shown in Figure 7 page 6 If recessing into a wall you can avoid extra framing by position ing your fireplace against an already existing framing member Do not recess termination cap into a wall or siding You may paint the term...

Страница 5: ...mantels at any height above the fireplace Note Noncombustible mantels may discolor Pre Installation Preparation Continued Figure 4 Framing Clearances for Installation Against an Exterior Wall C B A D E F G Top of Louver Opening 3 2 1 4 5 6 7 Wall Figure 5 Framing Clearances for Corner Installation Ref Mantel Ref Mantel from Top Depth of Louver Opening 1 14 A 16 2 12 B 14 3 10 C 12 4 8 D 10 5 6 E 8...

Страница 6: ...ove paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall extend a minimum of 24 61 cm above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 45 7 cm vent shall not terminate directly above a side walk or paved dri...

Страница 7: ...oid the warranty NOTICE Do not seal termination cap to vent pipe Cap must be removable for vent inspection and maintenance Installation Precautions Wear gloves and safety glasses for protection Use extreme caution when using ladders or when on roof tops Be aware of electrical wiring locations in walls and ceilings The following actions will void the warranty on your venting system Installation of ...

Страница 8: ...e vent will be terminated If the wall being penetrated is constructed of noncombustible material such as masonry block or concrete a 8 1 2 hole with zero clearance is acceptable see Figure 9 WARNING Do not recess vent termination into any wall This will cause a fire hazard 6 Noncombustible Exterior Wall Position the horizontal vent cap in the center of the 8 1 2 round hole and attach to the exteri...

Страница 9: ...ation The pipe overlap should be a minimum of 11 4 9 Combustible Exterior Wall Only Slide wall firestop against interior wall surface and attach with screws provided See Figure 13 for horizontal termination details 10 Place fireplace into position and shim with noncombustible material if needed Nail or screw side flanges to framing to secure unit in place IMPORTANT Make sure fireplace is level bef...

Страница 10: ...d Adjustable Pipe 12 Max Figure 14 Horizontal Termination Configuration for Square and Round Terminations 45 Elbow Wall Firestop Horizontal Round Termination Exterior Portion of Wall Firestop Round Termination Only Round Termination Horizontal Termination Configurations Figures 14 through 18 show different configurations and alterna tives for venting with horizontal termination Each figure include...

Страница 11: ...el Termination Wall Firestop 90 Elbow 45 Elbow Figure 16 Snorkel Termination Configurations for Below Ground Installation 12 Minimum Adequate Drainage HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90 elbows 45 Elbow Venting with Two 90 Elbows Vertical V Horizontal Horizontal H1 H1 Horizo...

Страница 12: ...bove is an attic space or insulated area install firestop above framed hole 2 Assemble the desired lengths of pipe and elbows necessary to reach from the fireplace flue up through the firestop Be sure all pipe and elbow connections are fully twist locked see Figure 8 page 8 3 Cut a hole in the roof using the locating hole as a center point Cover any exposed open vent pipes before cutting hole in r...

Страница 13: ...re 22 Vertical Venting Configuration Using One 90 Elbow Vertical Round High Wind Termination Shown Note Install restrictor into inner collar of fireplace as shown Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure 23 Vertical Venting Configuration Using Two 90 Elbows Vertical Round High Wind Termination ...

Страница 14: ...ation Kit Galvanized HTS 58 Horizontal Square Termination Kit Galvanized HTKS 58 Horizontal Square Termination Kit VT 58 Vertical Round Termination Galvanized ST 58 14 14 Snorkel Termination Galvanized ST 58 36 36 Snorkel Termination Galvanized SC 58 Storm Collar Galvanized Number Description WF 58 Wall Firestop Galvanized RF 58 6 Roof Flashing 0 to 6 12 Pitch Galvanized RF 58 12 Roof Flashing 6 1...

Страница 15: ...peed Control Control Shaft Locknut Control Knob Switch Bracket Duplex Outlet Located underneath firebox floor against lower right outside wall Blower Plug In V a r i a b l e F a n S w i t c h W h i t e W h i t e B l a c k G r e e n O n 1 1 0 1 1 5 V A C B l o w e r M o t o r B l a c k B l a c k B l a c k O f f Figure 27 Location of Wiring Diagram Decal Model May Vary From Illustration Wiring Diagr...

Страница 16: ...ower Wiring Diagram CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause im proper and dangerous operation Verify proper opera tion after servicing Installing Gas Piping to Fireplace Location WARNING Aqualifiedservicepersonmustconnect fireplace to gas supply Follow all local codes CAUTION For propane LP units never connect fireplace directly to the propane...

Страница 17: ...y gently pulling forward 2 Route flexible gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas supply to control valve see Figure 32 4 Check all gas connections for leaks See Checking Gas Connections Figure 32 Connecting Flexible Gas Line to Control Valve Cont...

Страница 18: ...itch GWMS2 1 Connect one terminal of 25 ft wire for wall switch to the TPTH terminal on valve Connect remaining wire terminal to TH terminal on valve Make sure wire terminals are in positions on unit as pictured in Figure 36 If wires are not connected as shown switch will not work 2 Route 25 ft wire through openings provided on sides of burner system to a convenient location to mount switch 3 Conn...

Страница 19: ...nd tape the remaining fragments onto the frame 1 Remove screen assembly by pushing the rod either left or right and then down and forward to remove screen rod assembly from the firebox Set assembly aside 2 Lift up on latches to unlock There are two on top of firebox and two below firebox that hold glass door in place see Figure 41 3 While holding glass door to prevent it from falling and causing i...

Страница 20: ...k and glowing embers Each log is marked with a number These numbers will help you identify the log when installing It is very important to install these logs exactly as instructed Do not modify logs Only use logs sup plied with fireplace Open louvers remove screen unlock door latches and open glass door See Removing Replacing Glass Door steps 1 and 2 on page 19 Install logs according to instructio...

Страница 21: ...touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repairit call a qualified service technician Force or attempted repair may result in a fire or explosio...

Страница 22: ... instructions included with the remote control NOTICE You must light the pilot before using the hand held remote control unit See Lighting Instruc tions page 21 After lighting let pilot flame burn for about one minute Turn control knob to ON position Adjust flame adjustment knob anywhere between HI and LO Slide the selector switch to the REMOTE position see Figure 50 Note The burnermay light ifhan...

Страница 23: ...room temperature If the hand held remote is misplaced obstructed or for any reason cannot transmit to the receiver the receiver will shut off the fireplace after 8 minutes Key Pad Lock Feature This feature allows the user to lock unlock the keypad on the hand held remote in the MANU or AUTO mode to prevent inadvertent operation i e children operating the hand held remote control etc The keypad is ...

Страница 24: ...ace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc GLASS DOOR WARNING Handle glass door panel with care Do not strike slam or otherwise abuse glass Do not op erate fireplace with the glass door removed cracked or broken WARNING Do not use abrasive cleaners as this maydamageglass Useanonabrasivehouseholdglass cleaner to clean glass Do not clean gl...

Страница 25: ... is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located behind the mounting bracket 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace pilot assembly 7 Replace pilot assembly 1 Turn on gas supply or open equipment shutoff valve 2 Turn g...

Страница 26: ...and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP or natural gas company 3 Clean burner see Cleaning and Main tenance page 24 or replace burner orifice 1 Adjust the log set so that the flame does not excessively impinge on it 2 Inspect the opening at the base of the burner to see that it is NOT packed with any type of material TR...

Страница 27: ... a clicking ticking noise just after burners are lit or shut off Remote does not function Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark residue on logs or inside of fireplace REMEDY 1 This is normal If noise is excessive contact qualified service person 1 Replace 9 volt batteries in receiver and hand ...

Страница 28: ... You may have further questions about installation operation or troubleshooting If so contact DESA s Customer Service Depart ment at 1 866 672 6040 When calling please have your model and serial numbers of your heater ready You can also visit DESA s technical service web site at www desatech com Replacement Parts Note Use only original replacement parts This will protect your warranty coverage for...

Страница 29: ...6P 36 Platinum LT36PB 36 Polished Brass Deflection hood Not Shown HD36 36 Black 2 Brow Perimeter Trim kit Not Shown PT36 36 Black PT36B 36 Brushed Brass PT36P 36 Platinum PT36PB 36 Polished Brass Manual blower Kit BK Manual variable control blower accessory provides better heat dis tribution Complete installation and operation instructions included in this manual Receiver and Hand Held THERMOSTAT ...

Страница 30: ...www desatech com 111923 01D 30 Illustrated Parts Breakdown MODELS V K36N V K36NH V K36P and V K36PH 6 7 20 17 18 13 2 12 19 8 1 4 11 9 14 3 16 5 10 2 10 1 10 8 10 5 10 4 10 9 15 21 10 6 10 3 10 7 ...

Страница 31: ... Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 111958 01 Log Set 2 10 1 111933 01 Left Base Log 1 10 2 111932 01 Right Base Log 1 10 3 111961 01 Left Front Log 1 10 4 111960 01 Right Front Log 1 10 5 111926 01 Right Rear Log 1 10 6 111929 01 Middle Crossover Log 1 10 7 111959 01 Left Rear Log 1 10 8 111930 01 Left Crossover Log 1 10 9 111962 01 Right Crosso...

Страница 32: ...www desatech com 111923 01D 32 1 2 3 4 5 12 12 7 15 10 12 13 9 11 TPTH TP TH 5 6 12 17 14 8 16 Illustrated Parts Breakdown BURNER ASSEMBLIES FOR MODELS V K36N V K36NH V K36P and V K36PH ...

Страница 33: ... Bottom 1 4 26808 Valve Bracket 1 5 11107 Screw 10 32 x 1 4 PPH Zinc 4 6 111310 01 Firebox Bottom 1 7 11102 Screw 8 32 x 3 8 PPH Zinc 2 8 111912 01 Tubing Assembly 1 9 111288 02 Flex Gas Line 1 10 108084 02 Pilot Assembly Natural Gas 1 108084 03 Pilot Assembly Propane LP Gas 1 11 14389 Hi Lo Natural Gas Valve 1 14390 Hi Lo Propane LP Gas Valve 1 12 11165 Screw 10 x 5 8 HWH Zinc 22 13 111913 02 Bur...

Страница 34: ...______________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ______________________________________...

Страница 35: ...______________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ______________________________________...

Страница 36: ...ated to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANYAND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION OF ANYAND ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO 2 YEARS ONALL COMP...

Отзывы: