                                                                                                        - 8 -                                         

For more information, visit www.desatech.com 

MANTELS 
 

A mantel may be installed if desired (see figure 18 & 19), 
Woodwork such as wood trims, mantels, or any other 
combustible material projecting from the front face must not 
be placed within 12 inches of the fireplace opening (and 
within 9 inches of the top louver opening).  Combustible 
materials above 12 inches and projecting more than 1-1/2 
inches from the fireplace must not be placed less than 12 
inches from the top opening of the fireplace (NFPA STD 211, 
Sec. 7-3.3.3). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

OPERATING GUIDELINES AND MAINTENANCE 

INSTRUCTIONS 

 
GLASS DOORS 
 

Glass doors are optional with the fireplace.  When the 
fireplace is in operation, doors must in FULLY OPENED or 
FULLY CLOSED position only or a fire hazard may be 
created (see figure 20). 
A fireplace equipped with glass doors operates much 
differently than a fireplace with an open front.  A fireplace 
with glass doors has a limited amount of air for combustion.  
Excessive heat within the fireplace can result if too large a fire 
is built or if the combustion air gate is not completely open.  
The following tips should be followed to assure that both the 
fireplace and the glass door retain their beauty and function 
properly.  Both the flue damper and the glass doors must be 
fully opened before starting the fire.  This will provide 
sufficient combustion air and maintain safe temperatures in 
the firebox. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
IMPORTANT:

 The glass must be allowed to warm slowly 

and evenly.  The tempered glass will withstand a gradual 
temperature rise to 550 degrees Fahrenheit, which is more 
than a normal fire will generate.  Such materials as pitch/wax 
laden logs, very dry mill end lumber, and large amounts of 
paper or cardboard boxes can create an excessively hot fire 
and should not be burned in this fireplace.  Always keep the 
fire well back from the doors and never allow flames to 
contact the glass. 
 
 
 
 
 
 
 

 
CLEANING THE GLASS 

 
Clean the glass with any commercial glass cleaner or soap and 
water.  Do not use any abrasive material to clean the glass.  Do 
not clean the glass with any cool water if the glass is still hot 
from the fire and smoke. 

Figure 20               GLASS DOORS 

WARNING

: Fireplaces equipped with glass doors

should be operated only with doors fully opened or doors
fully closed.  Doors, if left partly open, may draw gas and
flame out of the fireplace opening creating risks of both
fire and smoke. 

Figure 18           MANTEL CLEARANCE 

Figure 19         MANTEL CLEARANCE 

Содержание VB42

Страница 1: ...approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 st...

Страница 2: ...DE AIR KIT INSTALLATION PG 3 7 FAN BLOWER KIT ASSEMBLY PG 4 8 CHIMNEY PIPE AND OFFSET INSTALLATION PG 4 5 9 FIRESTOP SPACERS PG 5 10 FLASHING AND TERMINATION PG 6 7 11 FINISHING YOUR FIREPLACE PG 7 12...

Страница 3: ...l to Opening of unit 12 minimum Top Spacers 0 minimum Mantel Clearances see page 8 Mantels Chimney Outer Pipe Surfaces 2 minimum MINIMUM MAXIMUM CHIMNEY HEIGHT The minimum height of the chimney measur...

Страница 4: ...the fireplace HEARTH EXTENSION A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of the fireplace opening is required to protect combustible floor construct...

Страница 5: ...nd a wire spacer The pipe sections must be assembled independently as the chimney is installed When connecting chimney directly to the fireplace the inner flue pipe section must be installed first wit...

Страница 6: ...ipe passes through a framed opening into an attic space the firestop must be placed into an attic floor as shown in figure 11 PENETRATING THE ROOF OFFSET RISE A B 48 36 24 18 12 4 3 8 16 3 8 9 3 4 25...

Страница 7: ...ASHING INSTALLATION V6F 8DM or V12F 8DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cov...

Страница 8: ...prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 inches center to center and stacked at vertical height difference of 18 inches see figure 1...

Страница 9: ...lowed to assure that both the fireplace and the glass door retain their beauty and function properly Both the flue damper and the glass doors must be fully opened before starting the fire This will pr...

Страница 10: ...for fitting connection see figure 22 NOTE Secure incoming gas line to wood framing to provide rigidity for threaded end STEP 4 Repack insulation around gas line and into sleeve opening Seal any gaps b...

Страница 11: ...ace see figure 24 FOR FURTHER OPERATING GUIDELINES INSTRUCTIONS AND WARRANTY INFORMATION PLEASE REFER TO YOUR HOMEOWNERS GUIDE OR CONTACT YOUR AUTHORIZED DEALER TECHNICAL SERVICE You may have question...

Страница 12: ...AMPER 1 44 11308 RIVET ALUMINUM 4 15 108298 02 WELDMENT FRONT FACE 1 45 11412 COTTER PIN 1 1 2 x 1 16 2 15a 108298 01 WELDMENT FRONT FACE 1 46 14607 SWITCH ROCKER 1 16 108302 01 DEFLECTOR AIR 1 47 146...

Страница 13: ...11a For more information visit www desatech com ILLUSTRATED PARTS...

Страница 14: ...12 For more information visit www desatech com REPLACEMENT PARTS ACCESSORY PARTS...

Отзывы: