*  A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional CSA/AGA design-certified
equipment shutoff valve from your dealer. See Accessory, page 18.

Tee Joint

Reducer
Bushing to
1/8" NPT

1/8" NPT
Plug Tap

Test
Gauge
Connection *

Pressure
Regulator

Tee
Joint

Pipe
Nipple

Cap

Sediment Trap

Heater
Cabinet

3/8" NPT
Pipe Nipple

Ground Joint Union

Equipment
Shutoff Valve *

From
Gas Meter
(4" W.C. to
10.5" W.C.
Pressure)

Figure 12 - Gas Connection

3" Minimum

CONNECTING TO GAS
SUPPLY

 WARNING: A qualified ser-

vice person must connect heater
to gas supply. Follow all local
codes.

IMPORTANT:

 Check gas line pressure be-

fore connecting heater to gas line. Gas line
pressure must be no greater than 14 inches
of water. If gas line pressure is higher,
heater regulator damage could occur.

Installation must include an equipment shutoff
valve, ground joint union, and plugged
1/8" NPT tap. Locate NPT tap within reach
for test gauge hook up. NPT tap must be
upstream from heater (see Figure 12).

IMPORTANT:

 Install an equipment shutoff

valve in an accessible location. The equip-
ment shutoff valve is for turning on or
shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged heater valves.

Install sediment trap (trap) in supply line as
shown in Figure 12. Locate sediment trap
where it is within reach for cleaning. Locate
sediment trap where trapped matter is not
likely to freeze. A sediment trap traps mois-
ture and contaminants. This keeps them
from going into heater controls. If sediment
trap is not installed or is installed wrong,
heater may not run properly.

IMPORTANT:  

Hold pressure regulator

with wrench when connecting it to gas pip-
ing and/or fittings.

 

 CAUTION: Use only new,

black iron or steel pipe. Internally-
tinned copper tubing may be used
in certain areas. Check your local
codes. Use pipe 3/8" diameter or
greater to allow proper gas
volume to heater. If pipe is too
small, undue loss of pressure will
occur.

 WARNING: Never connect

heater to private (non-utility) gas
wells. This gas is commonly
known as wellhead gas.

 

 CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

INSTALLATION

Continued

Continued

 WARNING: This appliance re-

quires a 3/8" NPT (National Pipe
Thread) inlet connection to the
pressure regulator.

Содержание Vanguard VN1000BTA

Страница 1: ...st be performed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration service or maintenance can cause injury or property dam age Refer to this manual for correct installation and opera tional procedures For assis tance or additional informa tion consult a qualified in staller service agency or the gas supplier WARNING Thisisanunvented gas...

Страница 2: ... to run properly This heater has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 5 Keep all air openings in front and bot tom of heater clear and free of debris This will insure enough air for proper combustion 6 If heater shuts off do not relight until you provide fres...

Страница 3: ...ill Guard Glass Panel Front Panel Control Knob Ignitor Button 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater UNPACKING PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen DepletionSensing ODS safetyshutoffsys tem The ODS pilot is...

Страница 4: ...hose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggre gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubicfeetper1 000Btuperhour 4 8m3per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in whichtheappliancesareins...

Страница 5: ... draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ______________ Btu Hr maximum the space can support ______________ Btu Hr actual amount of Btu Hr used Example 46 100 Btu Hr maximum the space can support 50 000 Btu Hr actual amount of Btu Hr used The space in the above example is a confined sp...

Страница 6: ...on for required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces Figure 3 Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide e...

Страница 7: ...nal CSA AGA de sign certifiedequipmentshutoffvalvefrom your dealer See Accessory page 18 LOCATING HEATER This heater is designed to be mounted on a wall WARNING Maintain the mini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ancesfromfloor ceiling andjoin ing wall CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor locatehea...

Страница 8: ... thick wall shown Solid Wall 1 16 Space Figure 8 Tightening Anchors INSTALLATION Continued Placing Heater On Mounting Screws 1 Locate two keyhole slots on back panel of heater see Figure 9 2 Place large openings of slots over screwheads Slide heater down until screws are in small portion of slots Figure 11 Installing Bottom Mounting Screw Figure 9 Location Of Keyhole Slots On Back Panel Of Heater ...

Страница 9: ...ssible location The equip ment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves Install sediment trap trap in supply line as shown in Figure 12 Locate sediment trap where it is within reach for cleaning Locate se...

Страница 10: ...e OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 14 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas To Appliance page 11 8 Replace front panel ON POSITION OFF...

Страница 11: ...onds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a qualified service person or gas supplier for repairs CAUTION Donottrytoadjust heatinglevelsbyusingtheequip ment shutoff valve Note If pilot goes out repeat steps 3 through 7 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 8 Turn control kno...

Страница 12: ...ch use Have heaterinspectedyearlybyaquali fied service person Heater may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc 1 2 GLASS HEIGHT Figure 19 Correct Burner Flame Pattern Figure20 IncorrectBurnerFlamePattern Yellow Tipping 1 2 GLASS HEIGHT Ifburnerflamepatternisincorrect asshown in Figure 20 turn heater off see To Turn Off Gas to Appliance page ...

Страница 13: ...ng Keep ignitor cable dry 5 Tighten nut holding piezo ignitor to heater cabinet Nut is located inside heater cabinet at top 6 Replace ignitor cable 7 Replace piezo ignitor 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat igniting operation until air is re moved 5 Cl...

Страница 14: ...local natural gas company 3 Replace gas regulator 1 Problem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local natural gas company 3 Observe minimum installation clear ances see Figure 4 page 7 4 Clean burner see Cleaning and Mainte nance page 12 or replace burner orifice...

Страница 15: ...ement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROBLEM Heater produces a clicking ticking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Ga...

Страница 16: ...16 104265 BLUE FLAME 10 000 BTU NATURAL GAS HEATER 12 2 12 1 ODS PILOT ILLUSTRATED PARTS BREAKDOWN VN1000BTA 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 21 22 24 14 20 23 19 ...

Страница 17: ...M11084 38 Screw 8 x 3 8 8 9 098352 03BR Deflector Unit 1 10 098271 03 Ignitor Cable 1 11 098249 01 Nut M5 2 12 100701 03 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 104263 01 Burner 1 14 099387 11 Pilot Tubing 1 15 104259 05 Injector 1 piece 1 16 NJF 8C Hex Nut 1 17 099415 14 Pressure Regulator 1 18 104261 01 Burner Tubing 1 19 104264 01 Regulator Tubin...

Страница 18: ...ed dealer from whom you purchased this product If they cannot sup ply original replacement part s call DESA International s Technical Service Depart ment at 1 800 323 5190 for referral infor mation When contacting your dealer or DESA International have ready your name and address model and serial numbers of your heater how heater was malfunctioning type of gas used propane LP or natural gas purcha...

Страница 19: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Страница 20: ...warranty TheheaterMUSTbeinstalledbyaqualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost l...

Отзывы: